Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: HOMEYER PRECISION MANUFACTURING

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of HOMEYER PRECISION MANUFACTURING in 16051 MO-HWY 47, MARTHASVILLE, MO 63357 (NAICS 332710). OSHA activity number 344693692.

Watch Homeyer Precision Manufacturing — free Get an email when a new federal OSHA severe-injury report for Homeyer Precision Manufacturing is published. One employer, no account, unsubscribe in one click.
Site address
16051 MO-HWY 47
City
MARTHASVILLE
State
MO
ZIP
63357
Mailing
P.O. BOX 247, MARTHASVILLE, MO 63357
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
48
Ownership type
A

3 citations on file for this inspection.

1910.147 C06 I C

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4048.00 · Current $2834.00 Reduced
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:  An employee who performed work requiring lockout, bandsaw blade change, was not included in the annual review for each authorized employee performing lockout work to review how lockout work was to be conducted.  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $2833.6
  • — Z (S) $4048

1910.147 C04 II B

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:  The lockout specific procedure for the Powermatic band saw incorrectly stated that de-energization required "unplug and lockout."  The machine could not be unplugged, but would be locked out at the machine disconnect.  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 D01 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.95(d)(1)(i): The sampling strategy was not design to identify employees for the inclusion in the hearing conservation program and to enable the proper selection of hearing protection:  Noise monitoring had not identified a punch press operator that was likely to be exposed to noise levels exceeding the action level of 85 dBA.  (The operator consistently wore hearing protection.)  Abatement documentation is required for this violation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View HOMEYER PRECISION MANUFACTURING's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344693692.