2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: SUPERCON, INCORPORATED

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUPERCON, INCORPORATED in 830 BOSTON TURNPIKE, SHREWSBURY, MA 01545 (NAICS 331422). OSHA activity number 344756002.

Watch Supercon, Incorporated — free Get an email when a new federal OSHA severe-injury report for Supercon, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
830 BOSTON TURNPIKE
City
SHREWSBURY
State
MA
ZIP
01545
Mailing
830 BOSTON TURNPIKE, SHREWSBURY, MA 01545
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331422
Employees
42
Ownership type
A

2 citations on file for this inspection.

1910.138 B

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $8096.00 · Current $5670.00 Reduced
29 CFR 1910.138(b): The employer did not base selection of appropriate hand protection on an evaluation of the performance characteristics of the hand protection relative to the tasks to be performed, conditions present, duration of use, and the hazards and potential hazards identified:    830 Boston Turnpike, Shrewsbury, MA:  As of May 15, 2020, the employer had not selected the appropriate hand protection to protect to employees operating the Fenn Swaging Machine number 6 from the potential hazards identified by the manufacturer and experienced by employees.  The first warning in the manufacturer's manual was to never wear gloves or use rags.  On May 15, 2020, an employee inserting material into the Swaging machine received severe hand injuries when the material being inserted violently spun and the gloves were caught on the material being worked.
Recent events (2)
  • — I (S) $5670
  • — Z (S) $8096

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    830 Boston Turnpike, Shrewsbury, MA: As of May 19, 2020, the employer had not performed the annual periodic inspection that ensured each procedure was inspected for inaccuracies during an actual energy control task and therefore did not inspect whether the procedures were being followed.  An authorized employee management official went machine-to-machine to have the company's only other authorized employee explain the procedure for each machine.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View SUPERCON, INCORPORATED's full OSHA safety record →