Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: AMERICAN ELEVATOR CO., INC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of AMERICAN ELEVATOR CO., INC in 1316 N.E. 12TH, OKLAHOMA CITY, OK 73117 (NAICS 333921). OSHA activity number 344855432.

Watch American Elevator CO., INC — free Get an email when a new federal OSHA severe-injury report for American Elevator CO., INC is published. One employer, no account, unsubscribe in one click.
Site address
1316 N.E. 12TH
City
OKLAHOMA CITY
State
OK
ZIP
73117
Mailing
1905 S. HARVARD AVE., OKLAHOMA CITY, OK 73128
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333921
Employees
21
Ownership type
A

3 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $5461.00 · Current $5461.00
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury:     On or about July 27, 2020, and at times prior to, the employer did not establish a program consisting of energy control procedures, employee training and periodic inspections for elevator servicing and maintenance activities, exposing the employee to the hazards including but not limited to electrical, struck-by, and caught-in.
Recent events (1)
  • — Z (S) $5461

1910.147 C04 I

Serious Gravity 10 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $5461.00 · Current $5461.00
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control  of potentially hazardous energy when employees were engaged in activities covered by this section:                                                                                                                                                                                                                                                         On or about July 27, 2020, and at times prior to,  written procedures were not developed, documented, or utilized to indicate the proper steps to control hazardous energy while equipment including the elevator cab motor are being services or replaced, exposing employees to hazards including but not limited to, electric shock, caught-in and struck by.
Recent events (1)
  • — Z (S) $5461

1910.147 C07 I

Serious Gravity 10 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $5461.00 · Current $5461.00
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:        On or about July 27, 2020, and at times prior to, the employer does not provided employees  performing servicing and maintenance activities on elevators with training in the control of hazardous energy, exposing employees to hazards, including but not limited to electrical, caught-in and struck-by.
Recent events (1)
  • — Z (S) $5461

View AMERICAN ELEVATOR CO., INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344855432.