Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,783,325Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: AMERICAN ARCHES

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMERICAN ARCHES in 11269 WINDFERN RD, SUITE B, HOUSTON, TX 77064 (NAICS 321213). OSHA activity number 344998174.

Watch American Arches — free Get an email when a new federal OSHA severe-injury report for American Arches is published. One employer, no account, unsubscribe in one click.
Establishment
AMERICAN ARCHES
Site address
11269 WINDFERN RD, SUITE B
City
HOUSTON
State
TX
ZIP
77064
Mailing
11269 WINDFERN RD, SUITE B, HOUSTON, TX 77064
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321213
Employees
4
Ownership type
A

3 citations on file for this inspection.

1910.305 B02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2892.00 · Current $1735.00 Reduced
29 CFR  1910.305(b)(2)(i):Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  On or about October 27, 2020, in the production shop, where employees are exposed to an electrocution hazard without having all electrical switches covered.
Recent events (2)
  • — I (S) $1735.2
  • — Z (S) $2892

1910.305 G01 IV A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring:  On or about October 27, 2020, in the production shop, where employees are exposed to an electrocution when using a flexible extension cord as a substitute for fixed wiring.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):   On or about October 27, 2020:  a. In the production shop, where employees are using a damaged orange and black extension cord that was connected to a Ryobi Chop Saw.     b. In the production shop, where employees are using a damaged orange extension cord that was connected to a router.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344998174.