OCALA, FL —
OSHA Inspection: DONARRA EXTRUSIONS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DONARRA EXTRUSIONS, LLC in 1811 SW 42ND AVENUE, OCALA, FL 34474 (NAICS 326199). OSHA activity number 345046577.
Where did this inspection happen?
- Establishment
- DONARRA EXTRUSIONS, LLC
- Site address
- 1811 SW 42ND AVENUE
- City
- OCALA
- State
- FL
- ZIP
- 34474
- Mailing
- 1811 SW 42ND AVENUE, OCALA, FL 34474
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 25
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.136 A
- Issued
- Penalty
- Initial $4681.00 · Current $2809.00 Reduced
General-duty citation text
29 CFR 1910.136(a):The employer did not ensure that each affected employee uses protective footwear when working in areas where there is a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, or when the use of protective footwear will protect the affected employee from an electrical hazard, such as a static-discharge or electric-shock hazard, that remains after the employer takes other necessary protective measures: a. At the manufacturer's site located at 1811 SW 42nd Ave. Ocala, FL, employees on or about December 3, 2020, were exposed to crushing and laceration hazards when operating a 500 Lbs. metal bin cart with plastic debris without any foot protection provided.
Recent events (2)
- — I (S) $2808.6
- — Z (S) $4681
1910.147 C06 I C
- Issued
- Penalty
- Initial $438.00 · Current $263.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C):Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being insp. a. At the manufacturer's site located at 1811 SW 42nd Ave. Ocala, FL, employees on or about December 3, 2020, were exposed to energy release hazards when employer did not inspect all of the extrusion line and waste handling machine's lock and tag out procedures with all employees using the process.
Recent events (2)
- — I (O) $262.8
- — Z (O) $438
More inspections at DONARRA EXTRUSIONS, LLC
OCALA, FL—2024-06-11 00:00:00
DONARRA EXTRUSIONS, LLC.
OCALA, FL—2015-04-16 00:00:00
DONARRA EXTRUSIONS, LLC.
OCALA, FL—2015-04-01 00:00:00
DONARRA EXTRUSIONS, LLC
View DONARRA EXTRUSIONS, LLC's full OSHA safety record →
More inspections in this industry (NAICS 326199)
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
LANESBOROUGH, MA—2026-07-08
LANSEN MOLD CO., INC.
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345046577.