1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: NOVALIS US, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NOVALIS US, LLC in 200 MUNEKATA DRIVE SE, DALTON, GA 30721 (NAICS 321918). OSHA activity number 345103089.

Watch Novalis US, LLC — free Get an email when a new federal OSHA severe-injury report for Novalis US, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
NOVALIS US, LLC
Site address
200 MUNEKATA DRIVE SE
City
DALTON
State
GA
ZIP
30721
Mailing
200 MUNEKATA DRIVE SE, DALTON, GA 30721
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
79
Ownership type
A

8 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 1 instance 8 exposed
Issued
Penalty
Initial $5266.00 · Current $3160.00 Reduced
29 CFR  1910.37(b)(2):Each exit was not clearly visible and marked by a sign reading "Exit":  On or about 01/14/2021, the emergency exit door leading outside of the maintenance (Fabrication/Weld) area, was not clearly marked as an "Exit". Employees assigned to, and/or who work in the area were potentially exposed to fire and health hazards.
Recent events (2)
  • — I (S) $3159.6
  • — Z (S) $5266

1910.147 C04 II B

Serious Gravity 10 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $12288.00 · Current $7373.00 Reduced
29 CFR  1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline all of the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:    On or about 01/14/2021, the company's energy control program was deficient, in that specific procedural steps or additional methods and instructions for the control of hazardous energy sources were not developed and/or utilized by employee tasked with completing servicing and/or maintenance activities. Employees who service/maintain equipment such as, but not limited to, the (Suzhou Kisinhom) continuous conveyor, model no. - TR 1400 located in the center of the main UV production area, were potentially exposed to hazards created by the unexpected start-up and/or energization of the machinery. Energy sources used at facility include, but are not limited to, electrical and pneumatic energy.
Recent events (2)
  • — I (S) $7372.8
  • — Z (S) $12288

1910.147 C07 I A

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $12288.00 · Current $7373.00 Reduced
29 CFR  1910.147(c)(7)(i)(A):Authorized employee(s) received inadequate training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  On or about 01/14/2021, training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation was not provided too employees authorized to perform maintenance, and/or servicing activities at the facility. Employees who service/maintain equipment such as, but not limited to, the (Suzhou Kisinhom) continuous conveyor, model no. - TR 1400 located in the center of the main UV production area were not protected from hazards created by the unexpected start-up and/or energization of the machinery.
Recent events (2)
  • — I (S) $7372.8
  • — Z (S) $12288

1910.212 A03 II

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $12288.00 · Current $7373.00 Reduced
29 CFR  1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):   On or about 01/11/2021, adequate guarding to prevent inadvertent contact with the rollers of the UV line, and the robotic cells located at the ends of line 1 and line 2, was not installed. Employees completing quality control activities such as, but not limited to, cleaning lacquer from the 62 inch roller for the (Suzhou Kisinhom) continuous conveyor or retrieving empty wooden pallets were exposed to pinch point, stuck- by or caught -in/caught between hazards.
Recent events (2)
  • — I (S) $7372.8
  • — Z (S) $12288

1910.303 E

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $7022.00 · Current $4213.00 Reduced
29 CFR  1910.303(e): Markings were not provided on electrical equipment giving voltage, current, wattage, and other ratings as necessary:     On or about 01/14/2021, labeling to identify the voltage, current, wattage, and other required ratings was not marked on the electrical multi-load panel boxes and/or equipment used at the facility. Continuously accessing the panel boxes may allow dirt and debris to contact the internal wiring of the unit, resulting in possibility of arcing. Employees tasked with servicing/maintaining the electrical panel for equipment such as, but not limited to, UV Line 1, Lockout Point EL-029 located in the UV Production Line were potentially exposed to electrical hazards
Recent events (2)
  • — I (S) $4213.2
  • — Z (S) $7022

1910.1200 H01

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $5266.00 · Current $3160.00 Reduced
29 CFR  1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  On or before 01/14/2021, employees were not trained on the hazardous chemicals utilized in the workplace. Chemicals used at the site include, but are not limited to, UV Sealer Base Coat, Acetone, Isopropyl Alcohol, and Vinyl Lacuer Matte HP.
Recent events (2)
  • — I (S) $3159.6
  • — Z (S) $5266

1910.1200 H03 IV

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(h)(3)(iv):  The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information:  a) UV Line Production Area:  On or about 01/14/2020, employer failed to provide training or information to employees working with hazardous chemicals on the details of outline in the new Hazard Communication standard which encompasses the Global Harmonization System (GHS).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F06 I

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $5266.00 · Current $3160.00 Reduced
29 CFR  1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v):  a). On or about 01/14/2021, the employer did not ensure that appropriate labels and/or hazard warnings were not placed on secondary container of  possible hazardous chemicals.  Chemicals such as, but not limited to; UV Sealer Base Coat and Vinyl Lacuer Matte HP were not properly labeled.
Recent events (2)
  • — I (S) $3159.6
  • — Z (S) $5266

View NOVALIS US, LLC's full OSHA safety record →