DENVER, CO —
OSHA Inspection: TRANSDEV SERVICES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRANSDEV SERVICES, INC. in 7500 EAST 41ST AVENUE, DENVER, CO 80216 (NAICS 485991). OSHA activity number 345160345.
Where did this inspection happen?
- Establishment
- TRANSDEV SERVICES, INC.
- Site address
- 7500 EAST 41ST AVENUE
- City
- DENVER
- State
- CO
- ZIP
- 80216
- Mailing
- 7500 EAST 41ST AVENUE, DENVER, CO 80216
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 485991
- Employees
- 76
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $5471.00 · Current $5471.00
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) Transdev Services, Inc., at 7500 E 41st Avenue, Denver, CO: On and preceding 2/17/2021, the employer did not ensure that a written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was established and implemented for required respirator use. Employees were required to wear 3M model 07182 half mask air purifying respirators with P100 filters when welding, spray painting, or grinding. The employer had not established and implemented a written respiratory protection program. This condition exposed employees to a respiratory hazard.
Recent events (1)
- — Z (S) $5471
1910.134 E01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Transdev Services, Inc., at 7500 E 41st Avenue, Denver, CO: On and preceding 2/17/2021, the employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was required to use the respirator in the workplace. Employees were required to wear 3M model 07182 half mask air purifying respirators with P100 filters when welding, spray painting, or grinding. Employees were not provided a medical evaluation prior to use. This condition exposed employees to a respiratory hazard.
Recent events (1)
- — Z (S) $0
1910.134 K
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k): The employer did not provide effective, comprehensive, understandable, annual respirator training to employees who are required to use respirators: (a) Transdev Services, Inc., at 7500 E 41st Avenue, Denver, CO: On and preceding 2/17/2021, the employer did not provide annual comprehensive, understandable training. Employees were required to wear 3M model 07182 half mask air purifying respirators with P100 filters when welding, spray painting, or grinding. The employees did not receive comprehensive respirator training. This condition exposed employees to a respiratory hazard.
Recent events (1)
- — Z (S) $0
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $5471.00 · Current $5471.00
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Transdev Services, Inc., at 7500 E 41st Avenue, Denver, CO: On and preceding 2/17/2021, the employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. Employees performed maintenance of buses. The buses were raised using auto lifts during maintenance. Employees were exposed to mechanical, electrical, and potential energy sources of the raised buses. The LOTO procedure was last inspected 1/15/2020. This condition exposed employees to uncontrolled energy hazards. (b) Transdev Services, Inc., at 7500 E 41st Avenue, Denver, CO: On and preceding 2/17/2021, the employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. Employees and contractors performed maintenance of a Champion Advantage air compressor. The air compressor had electrical and pneumatic energy sources. The LOTO procedure was last inspected 1/15/2020. This condition exposed employees to uncontrolled energy hazards.
Recent events (1)
- — Z (S) $5471
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: (a) Transdev Services, Inc., at 7500 E 41st Avenue, Denver, CO: On and preceding 2/17/2021, the employer did not ensure that authorized employees received training in the recognition of applicable hazardous energy sources and the methods and means necessary for energy isolation. Employees performed maintenance, including work involving the air filter, of a Champion Advantage air compressor. The air compressor had electrical and pneumatic energy sources. The compressed air was not bled from the air compressor prior to performing service. The employer did not ensure that employees recognized the compressed air as a hazardous energy source and did not train employees to relieve the stored energy prior to servicing the air compressor. This condition exposed employees to an uncontrolled energy hazard.
Recent events (1)
- — Z (S) $0
1910.147 D05 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: (a) Transdev Services, Inc., at 7500 E 41st Avenue, Denver, CO: On and preceding 2/17/2021, the employer did not ensure that all potentially hazardous stored or residual energy was relieved or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices. Employees performed maintenance, including work involving the air filter, of a Champion Advantage air compressor. The air compressor had electrical and pneumatic energy sources. The compressed air was not bled from the air compressor prior to performing service. This condition exposed employees to an uncontrolled energy hazard.
Recent events (1)
- — Z (S) $0
1910.1200 F06 I
- Issued
- Abate by
- Penalty
- Initial $5471.00 · Current $5471.00
General-duty citation text
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v): (a) Transdev Services, Inc., at 7500 E 41st Avenue, Denver, CO: On and preceding 2/17/2021, the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier, signal word, hazard statement, pictogram, and precautionary statement. Employees used Zep DZ-7 Neutral Disinfectant Cleaner to disinfect surfaces. The disinfectant was placed in spray bottles for use. The secondary containers were not provided with labels nor were they marked with the identification or hazard information of the contents. This condition exposed employees to a chemical hazard. (b) Transdev Services, Inc., at 7500 E 41st Avenue, Denver, CO: On and preceding 2/17/2021, the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier, signal word, hazard statement, pictogram, and precautionary statement. An employee fueled buses from an approximate 10000 gallon tank. The tank was labeled "Flammable" and "Unleaded". The content of the tank was not identified nor was complete hazard information provided. This condition exposed an employee to a chemical hazard.
Recent events (1)
- — Z (S) $5471
1910.1200 G08
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not ensure that Safety Data Sheets were readily accessible during each work shift to employees when they were in their work area(s): (a) Transdev Services, Inc., at 7500 E 41st Avenue, Denver, CO: On and preceding 2/17/2021, the employer did not ensure that Safety Data Sheets were readily accessible during each work shift to employees when they were in their work area. Employees used chemicals, including but not limited to Simple Green All Purpose Cleaner, Zep Glass Cleaner, Zep DZ-7 Neutral Disinfectant Cleaner, and Round Up herbicide, at the office building of the complex. SDSs for chemicals stored or used at the office building were not accessible in the office building. This condition exposed employees to a chemical hazard.
Recent events (1)
- — Z (S) $0
More inspections at TRANSDEV SERVICES, INC.
NORTH LAS VEGAS, NV—2025-06-26
TRANSDEV SERVICES, INC.
CAPITOL HEIGHTS, MD—2024-05-02 00:00:00
TRANSDEV SERVICES, INC.
BOSTON, MA—2024-03-26 00:00:00
TRANSDEV SERVICES, INC.
SAN DIEGO, CA—2024-02-08 00:00:00
TRANSDEV SERVICES INC
DENVER, CO—2021-11-10 00:00:00
TRANSDEV SERVICES, INC.
View TRANSDEV SERVICES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 485991)
SALEM, OR—2026-05-20
317744210 - WVT EUGENE CORPORATION
LAKEWOOD, WA—2026-04-08
WA317990340 - TRANSDEV SERVICES INC
CABO ROJO, PR—2026-03-16
ELDERLY TRANSPORTATION SERVICES, LLC
FEDERAL WAY, WA—2026-03-05
WA317990178 - NEW PACIFIC NORTHWEST ENTERPRISES LLC
CHICO, CA—2026-01-29
DRIVERGE VEHICLE INNOVATIONS, LLC
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source