Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: TREVIICOS SOUTH CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TREVIICOS SOUTH CORPORATION in 43591 US HIGHWAY 27 N, CLEWISTON, FL 33440 (NAICS 237990). OSHA activity number 345164594.

Watch Treviicos South Corporation — free Get an email when a new federal OSHA severe-injury report for Treviicos South Corporation is published. One employer, no account, unsubscribe in one click.
Site address
43591 US HIGHWAY 27 N
City
CLEWISTON
State
FL
ZIP
33440
Mailing
38 3RD AVE, 3RD FLOOR, CHARLESTOWN, MA 02129
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237990
Employees
15
Ownership type
A

2 citations on file for this inspection.

1926.501 B01

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $11703.00 · Current $11703.00
1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  On or about February 25, 2021, on the top of a bentonite mixer located at Treviicos South worksite in Clewiston, Florida, the employer did not provide and install a fall protection system where an employee was exposed to a fall hazard of approximately 8 feet, 1 inches while repairing a leak on a keystone valve powered by a pneumatic rotary actuator.
Recent events (2)
  • — I (O) $11703
  • — Z (S) $11703

1926.417 A

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $13653.00 · Current $8192.00 Reduced
1926.417(a): Controls that were to be deactivated during the course of work on energized or de-energized equipment or circuits were not tagged:  On or about February 25, 2021, at the surrounding area of the bentonite mixer located at Treviicos South worksite in Clewiston, Florida, the employer did not establish a LOTO program where employees were exposed to amputation hazards due to not de-energizing the pneumatic rotary actuator  while performing routine maintenance.
Recent events (2)
  • — I (S) $8192
  • — Z (S) $13653

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345164594.