1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: SEOHAN AUTO USA

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SEOHAN AUTO USA in 2590 INNOVATION DRIVE, AUBURN, AL 36832 (NAICS 336111). OSHA activity number 345200455.

Watch Seohan Auto USA — free Get an email when a new federal OSHA severe-injury report for Seohan Auto USA is published. One employer, no account, unsubscribe in one click.
Establishment
SEOHAN AUTO USA
Site address
2590 INNOVATION DRIVE
City
AUBURN
State
AL
ZIP
36832
Mailing
246 TEAGUE COURT, AUBURN, AL 36832
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336111
Employees
170
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $12288.00 · Current $12288.00
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) On or about March 31, 2021 and times prior on the CO4 line, pull test section: Employees engaged in change-over activities involving 8-9 jigs were exposed to caught-in hazards in that the employer failed to ensure the machine specific energy control procedures were utilized to prevent the unexpected release of energy sources such as electric, pneumatic and hydraulic.
Recent events (2)
  • — I (S) $12288
  • — Z (S) $12288

1910.147 C06 I

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $12288.00 · Current $0.00 Reduced
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) On or about March 30, 2021 and times prior the annual lockout/tagout periodic inspection: The employer failed to perform a periodic review of the energy control procedures to ensure employees conducting work on equipment, such as jig change over, were adequately securing hazardous energy on equipment in accordance with the written machine specific energy control procedure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12288

1910.212 A03 II

Serious Gravity 10 1 instance 8 exposed
Issued
Penalty
Initial $12288.00 · Current $7612.00 Reduced
29 CFR  1910.212(a)(3)(ii):The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle:  a) On or about March 30, 2021 on the CO2 Clamper: The employer failed to ensure proper point-of-operation guarding was provided to protect the employee from having any part of their body in the danger zone during the operating cycle in that the light curtain was not connected to the clamping porting of the machine which allowed an employee to reach into the machine during the operation cycle.
Recent events (2)
  • — I (S) $7612
  • — Z (S) $12288

1910.303 G01

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(g)(1):Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) On or about March 31, 2021 two electrical panels (LB & HB) were blocked: The employer failed to ensure a clear and unobstructed path to electrical panels was maintained.