CHANNELVIEW, TX —
OSHA Inspection: K-SOLV, LP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of K-SOLV, LP in 1015 LAKESIDE DR, CHANNELVIEW, TX 77530 (NAICS 424690). OSHA activity number 345243349.
Where did this inspection happen?
- Establishment
- K-SOLV, LP
- Site address
- 1015 LAKESIDE DR
- City
- CHANNELVIEW
- State
- TX
- ZIP
- 77530
- Mailing
- 14133 MEMORIAL DRIVE STE 3, HOUSTON, TX 77079
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424690
- Employees
- 56
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.106 D05 VI A
- Issued
- Abate by
- Penalty
- Initial $9557.00 · Current $9557.00
General-duty citation text
29 CFR 1910.106(d)(5)(vi)(a): Where a storage building was located 50 feet or less from a building or line of adjoining property that may be built upon, the exposing wall was not a blank wall having a fire-resistance rating of at least 2 hours: Instance a). On or about April 7, 2021, at the K-Solv facility located in Channelview Texas, the employer did not ensure that storage warehouse building #2, located less than 50 feet from the maintenance building #4, had an exposing wall with at least 2-hour fire resistance rating. Instance b). On or about April 7, 2021, at the K-Solv facility located in Channelview Texas, the employer did not ensure that the storage warehouse building #3, located less than 50 feet from the main office building #1, had an exposing wall with at least 2-hour fire resistance rating.
Recent events (1)
- — Z (S) $9557
1910.106 E06 II
- Issued
- Abate by
- Penalty
- Initial $9557.00 · Current $9557.00
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 degree F (37.8 degree C), were dispensed into containers without the containers being electrically interconnected: On or about April 7, 2021, at the K-Solv facility located in Channelview Texas, the employer did not ensure that the transfer piping and 55-gallon metal drum were electrically interconnected (or bonded) while the flammable liquid mixture of naphthalene and toluene was dispensed into a 55-gallon drum from a 275-gallon tote in bay#1 area of the storage warehouse building #2.
Recent events (1)
- — Z (S) $9557
1910.106 E07 I B
- Issued
- Abate by
- Penalty
- Initial $9557.00 · Current $9557.00
General-duty citation text
29 CFR 1910.106(e)(7)(i)(b): Locations where flammable vapor-air mixtures existed under normal operations were not classified Class I, Division 1 according to the requirements of subpart S of this part: On or about April 7, 2021, at the K-Solv facility located in Channelview Texas, the employer did not classify locations in bay #1 area of warehouse building #2 where flammable vapor-air mixtures existed under normal operations as Class 1 Division 1 locations.
Recent events (1)
- — Z (S) $9557
1910.132 D01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: On or about April 7, 2021, and at times prior thereto, the employer did not require the use of face shields to protect employees performing transfer of liquid chemicals in Bay #1.
Recent events (1)
- — Z (O) $0
1910.157 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(g)(2): The employer did not provide the education required in paragraph (g)(1) of this section upon initial employment and at least annually thereafter. On or about April 7, 2021, the employer did not provide annual training on the use of portable fire extinguishers.
Recent events (1)
- — Z (O) $0
More inspections at K-SOLV, LP
CHANNELVIEW, TX—2023-06-30 00:00:00
K-SOLV, LP
CHANNELVIEW, TX—2012-12-27 00:00:00
K-SOLV, LP
CHANNELVIEW, TX—2007-04-19 00:00:00
K-SOLV, LP
View K-SOLV, LP's full OSHA safety record →
More inspections in this industry (NAICS 424690)
BEAVERTON, OR—2026-07-15 00:00:00
317744263 - INPRIA CORP
HOPKINS, MN—2026-07-13 00:00:00
111581 - CHEMSOL LLC
DEERFIELD BEACH, FL—2026-07-10 00:00:00
OXYGEN DEVELOPMENT, L.L.C.
KATONAH, NY—2026-07-08 00:00:00
STRATCHEM LOGISTICS LLC
PAWTUCKET, RI—2026-07-08 00:00:00
SOLVENT DIRECT
More inspections in TX
RICHMOND, TX—2026-07-17 00:00:00
CORNELIUS NURSERIES, INC.
HOUSTON, TX—2026-07-17 00:00:00
HOLLOWAY HOUSTON, INC.
BONHAM, TX—2026-07-17 00:00:00
VOLUNTARY PURCHASING GROUPS, INC.
SNYDER, TX—2026-07-16 00:00:00
RNWBL
WICHITA FALLS, TX—2026-07-16 00:00:00
UNITED RENTALS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345243349.