Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FORTIFIED METALS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FORTIFIED METALS, LLC in 1420 MARKUM RANCH ROAD EAST, FORT WORTH, TX 76126 (NAICS 332312). OSHA activity number 345318844.

Watch Fortified Metals, LLC — free Get an email when a new federal OSHA severe-injury report for Fortified Metals, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1420 MARKUM RANCH ROAD EAST
City
FORT WORTH
State
TX
ZIP
76126
Mailing
1420 MARKUM RANCH ROAD EAST, FORT WORTH, TX 76126
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
11
Ownership type
A

5 citations on file for this inspection.

1910.101 B

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $1989.00 · Current $1193.00 Reduced
29 CFR  1910.101(b):"Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tank cars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6.  On or about May 20, 2021 and times prior there to, the employer did not ensure that compressed gas cylinders were being stored securely and handled in accordance with the Compressed Gas Association. Employees exposed to injuries associated with explosions and struck by hazards:  a) Pressurized acetylene tank stored near front of shop in the welding area
Recent events (2)
  • — I (S) $1193.4
  • — Z (S) $1989

1910.253 B02 IV

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $1989.00 · Current $1193.00 Reduced
29 CFR  1910.253(b)(2)(iv):Valve protection caps, where cylinder is designed to accept a cap, shall always be in place, hand-tight, except when cylinders are in use or connected for use.  On or about May 20, 2021 and times prior there to, the employer did not ensure that employees were not exposed to struck by hazards where compressed gas cylinders were stored without their valve caps:  a) Pressurized acetylene tank stored near front of shop in the welding area
Recent events (2)
  • — I (S) $1193.4
  • — Z (S) $1989

1910.147 C01

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $5461.00 · Current $3277.00 Reduced
29 CFR  1910.147(c)(1):Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  On or about May 20, 2021 and times prior there to, the employer did not develop or implement written lockout/tagout procedures for each type of equipment or machine located within the manufacturing facility.  Employees performing maintenance work on the equipment such as but not limited to the R-Panel, Slip and Cut and other press type machines were exposed to electrical shock and amputation hazards
Recent events (2)
  • — I (S) $3276.6
  • — Z (S) $5461

1910.253 B02 II

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $1989.00 · Current $1193.00 Reduced
29 CFR  1910.253(b)(2)(ii):Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons.   On or about May 20, 2021 and times prior there to, employees were exposed to potential explosion hazards associated with a pressurized acetylene cylinder that was not chained or secured and was left free standing:  a) Front of shop area where welding equipment and supplies were stored.
Recent events (2)
  • — I (S) $1193.4
  • — Z (S) $1989

1910.305 G02 III

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $1989.00 · Current $1193.00 Reduced
29 CFR  1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that the strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.   On or about May 20, 2021 and times prior there to, employees were exposed to electroshock hazards caused by the main power flexible cable for the R-Panel Machine not being provided strain relief. The power cable had exposed wiring due to the friction and movement of being unplugged without being provided with strain relief.
Recent events (2)
  • — I (S) $1193.4
  • — Z (S) $1989

View FORTIFIED METALS, LLC's full OSHA safety record →