1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ST PAPER, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ST PAPER, LLC in 106 E. CENTRAL AVE., OCONTO FALLS, WI 54154 (NAICS 322121). OSHA activity number 345319941.

Watch ST Paper, LLC — free Get an email when a new federal OSHA severe-injury report for ST Paper, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ST PAPER, LLC
Site address
106 E. CENTRAL AVE.
City
OCONTO FALLS
State
WI
ZIP
54154
Mailing
106 E. CENTRAL AVE., OCONTO FALLS, WI 54154
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322121
Employees
90
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 2 instances 8 exposed
Issued
Abate by
Penalty
Initial $8778.00 · Current $8778.00
29 CFR  1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)[A], (c)(4)(ii)[B], (c)(4)(ii)[C], and (c)(4)(ii)[D]:    On or about May 20, 2021 the machine specific lockout procedure for the Wetlap Press Drive did not clearly and specifically outline the scope, purpose, authorization and magnitude(s) of energy encountered by employees performing servicing and/or maintenance tasks on the machine.
Recent events (2)
  • — I (S) $8778
  • — Z (S) $8778

1910.261 B01

Deleted Serious Gravity 10 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $12288.00 · Current $0.00 Reduced
29 CFR  1910.261(b)(1): Lockouts. Devices such as padlocks shall be provided for locking out the source of power at the main disconnect switch. Before any maintenance, inspection, cleaning, adjusting, or servicing of equipment (electrical, mechanical, or other) that requires entrance into or close contact with the machinery or equipment, the main power disconnect switch or valve, or both, controlling its source of power or flow of material, shall be locked out or blocked off with padlock, blank flange, or similar device.:   On or about May 17, 2021 the Andritz Wet Lap press was not locked when operators accessed the guarded area containing the head-box and front press rollers to throw pulp onto the wires, in an attempt to re-align them, exposing employees to caught in hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12288

1910.261 K01

Serious Gravity 10 2 instances 8 exposed
Issued
Penalty
Initial $12288.00 · Current $6144.00 Reduced
29 CFR  1910.261(k)(1):Emergency stops. Paper machines shall be equipped with devices that will stop the machine quickly in an emergency. The devices shall consist of push buttons for electric motive power (or electrically operated engine stops), pull cords connected directly to the prime mover, control clutches, or other devices, interlocked with adequate braking action. The devices shall be tested periodically by making use of them when stopping the machine and shall be so located that any person working on the machine can quickly disconnect the machine from the source of power in case of emergency:   a)	On or about May 17, 2021 the emergency pull wire installed on the Andritz Wet Lap press was not functional to stop the press in the event of an emergency.  The emergency pull wire on the tending side of the press broke when pulled and had not been tested periodically to ensure it was functioning during press operations.
Recent events (2)
  • — I (S) $6144
  • — Z (S) $12288

View ST PAPER, LLC's full OSHA safety record →