Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHEMTEX, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CHEMTEX, LLC in 143 GARRETT WAY NW, MILLEDGEVILLE, GA 31061 (NAICS 313230). OSHA activity number 345393458.

Watch Chemtex, LLC — free Get an email when a new federal OSHA severe-injury report for Chemtex, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CHEMTEX, LLC
Site address
143 GARRETT WAY NW
City
MILLEDGEVILLE
State
GA
ZIP
31061
Mailing
143 GARRETT WAY NW, MILLEDGEVILLE, GA 31061
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313230
Employees
35
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 10 instances 30 exposed
Issued
Penalty
Initial $8124.00 · Current $8124.00
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.  a) Production line; On or about June 21, 2021, the employer did not provide machine specific procedures for employees performing servicing and maintenance activities, exposing employees to amputation hazards.
Recent events (1)
  • — Z (S) $8124

1910.212 A03 II

Serious Gravity 10 1 instance 14 exposed
Issued
Penalty
Initial $8124.00 · Current $8124.00
29 CFR  1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a) Production line; On or about June 21, 2021, the employer did not ensure the Inline Rosenthal Sheeter (pad cutter); serial number 80849 and model number WA-S-6-HUBEAAA was guarded at the point of operation, exposing employees to amputation hazards.
Recent events (1)
  • — Z (S) $8124

1910.37 A04

Other-than-serious 1 instance 30 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times.  a) Exit door leading to parking lot; The employer did not ensure that the exit sign was operational exposing employees to caught in hazards.
Recent events (1)
  • — Z (O) $0

View CHEMTEX, LLC's full OSHA safety record →