KENILWORTH, IL —
OSHA Inspection: PREMIER ROOFING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PREMIER ROOFING INC. in 244 CUMNOR RD., KENILWORTH, IL 60043 (NAICS 238160). OSHA activity number 345429328.
Where did this inspection happen?
- Establishment
- PREMIER ROOFING INC.
- Site address
- 244 CUMNOR RD.
- City
- KENILWORTH
- State
- IL
- ZIP
- 60043
- Mailing
- 5568 N. LYNCH AVE, CHICAGO, IL 60630
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $4096.00 · Current $1758.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On July 20, 2021, employees engaged in roofing activity were not protected from fall hazards while working at an elevation of approximately 13 feet above the ground. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $1757.5
- — Z (S) $4096
1926.1053 B01
- Issued
- Penalty
- Initial $2926.00 · Current $1758.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On July 20, 2021, an extension ladder used by employees to access and egress the roof deck did not have its side rails extended at least 3 feet above the roof. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $1757.5
- — Z (S) $2926
More inspections at PREMIER ROOFING INC.
GRAND RAPIDS, MI—2022-05-09 00:00:00
PREMIER ROOFING, INC.
PLAINWELL, MI—2021-04-30 00:00:00
PREMIER ROOFING, INC.
COLONIAL HEIGHTS, VA—2020-12-18 00:00:00
PREMIER ROOFING, INC.
EMPORIA, VA—2019-11-19 00:00:00
PREMIER ROOFING, INC.
CHASE CITY, VA—2016-04-26 00:00:00
PREMIER ROOFING, INC
View PREMIER ROOFING INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
PORTLAND, OR—2026-07-17 00:00:00
317744797 - JBC ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
BRADLEY, IL—2026-07-16 00:00:00
JUAN CRUZ DBA ROOFBOYS LLC
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
More inspections in IL
FRANKFORT, IL—2026-07-17 00:00:00
QUANTUM TECHNICAL SERVICES INC.
ROCK ISLAND, IL—2026-07-17 00:00:00
AUGUSTANA COLLEGE
WASHINGTON, IL—2026-07-17 00:00:00
SUNRUN INSTALLATION SERVICES, INC.
FOREST PARK, IL—2026-07-17 00:00:00
CONSERVATION OF SCULPTURE & OBJECTS STUDIO, INC.
BLUE ISLAND, IL—2026-07-17 00:00:00
PROFLOW PUMPING SOLUTIONS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345429328.