Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FOREST PARK STUCCO, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FOREST PARK STUCCO, INC. in 516 WASHINGTON BLVD, OAK PARK, IL 60302 (NAICS 238140). OSHA activity number 345446280.

Watch Forest Park Stucco, INC. — free Get an email when a new federal OSHA severe-injury report for Forest Park Stucco, INC. is published. One employer, no account, unsubscribe in one click.
Site address
516 WASHINGTON BLVD
City
OAK PARK
State
IL
ZIP
60302
Mailing
541 MARENGO AVE., FOREST PARK, IL 60130
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.451 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2926.00 · Current $1463.00 Reduced
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):  a) On or about July 29, 2021, employees were exposed to electrical hazards while erecting, dismantling, and working from frame scaffolding in close proximity to a 120/240 volt overhead power line.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1463
  • — Z (S) $2926

1926.451 G01 I

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $2048.00 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:  a)  On July 28, 2021, employees working from a ladder jack scaffold were exposed to a fall hazard of approximately 25 feet.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2048
  • — Z (S) $4096

1926.452 K01

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(k)(1): Platforms exceeded a height of 20 feet (6.1 m):  a)  On Jul 28, 2021, employees were working from a ladder jack scaffold platform at a height of approximately 25 feet.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a)  On July 28, 2021, employees performing roofing work were exposed to fall hazards of approximately 11 feet.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View FOREST PARK STUCCO, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345446280.