RICHLAND, PA —
OSHA Inspection: RIGIDPLY RAFTERS, INCORPORATED
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RIGIDPLY RAFTERS, INCORPORATED in 701 EAST LINDEN STREET, RICHLAND, PA 17087 (NAICS 423310). OSHA activity number 345461750.
Where did this inspection happen?
- Establishment
- RIGIDPLY RAFTERS, INCORPORATED
- Site address
- 701 EAST LINDEN STREET
- City
- RICHLAND
- State
- PA
- ZIP
- 17087
- Mailing
- 701 EAST LINDEN STREET, RICHLAND, PA 17087
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423310
- Employees
- 120
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $8778.00 · Current $5000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Rigidply Rafters - The employer did not ensure that the procedures were developed, documented and utilized for the control of potentially hazardous energy for equipment including hydraulic pumps and Mann-Russell electronic generator, exposing employees to electrical hazards hazards on or before April 16, 2021. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $5000
- — Z (S) $8778
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Rigidply Rafters - The employer did not conduct annual periodic inspections of the energy control procedures and the employees utilizing the procedures on equipment such as but not limited to the Mann- Russell electronic generator, beam presses and Lam stacker exposing employees to hazards related to the unexpected start up or release of stored energy, on or about April 16, 2021. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $5266.00 · Current $5000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: a) Rigidply Rafters - The employer did not ensure that authorized employees received training to ensure employee had the knowledge and skills needed for the safe application, usage, and removal of energy control on equipment , exposing employees to electrical hazards on or about April 16, 2021. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $5000
- — Z (S) $5266
1910.147 C07 I B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Each affected employee was not instructed in the purpose and use of the energy control procedure. a) Rigid Ply Rafters- The employer did not ensure affected employees who conduct work in area where service and maintenance operations are conducted were instructed on the purpose and use the of the energy control procedures, on or about April 16, 2021. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 423310)
WILSON, NC—2026-07-09
161516 - STEPHENSON MILLWORK COMPANY, INC.
WILSON, NC—2026-07-09
161511 - WEB-DON, INCORPORATED
SANTA ANA, CA—2026-07-09
NGY GROUP (ORANGE COUNTY) INC.
HAVANA, FL—2026-07-08
BOISE CASCADE WOOD PRODUCTS, L.L.C.
OAKLAND, CA—2026-06-30
VAN MATRE LUMBER CO., INC.
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345461750.