PARK RIDGE, IL —
OSHA Inspection: CHRIS Z. CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CHRIS Z. CONSTRUCTION INC. in 1828 S. FAIRVIEW, PARK RIDGE, IL 60068 (NAICS 238110). OSHA activity number 345480990.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CHRIS Z. CONSTRUCTION INC.
- Site address
- 1828 S. FAIRVIEW
- City
- PARK RIDGE
- State
- IL
- ZIP
- 60068
- Mailing
- 4517 LILAC AVE., GLENVIEW, IL 60025
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B01
- Issued
- Aug 19, 2021
- Abate by
- Aug 25, 2021
- Penalty
- Initial $4,096 · Current $4,096
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On or about August 16, 2021, employees were exposed to the hazard of falling approximately 9 feet while walking/working at and along unprotected sides and edge of the first story deck. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — C (S) $4096
- — Z (S) $4096
1926.1053 B01
- Issued
- Aug 19, 2021
- Abate by
- Aug 25, 2021
- Penalty
- Initial $2,341 · Current $2,341
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder: a) On or about August 16, 2021, employees were exposed to the hazard of falling while climbing a portable ladder that did not extend above the landing surface of the first story deck. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — C (S) $2341
- — Z (S) $2341
More inspections in this industry (NAICS 238110)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345480990.