LEWISBURG, WV —
OSHA Inspection: BFL CONTRACTING, INC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of BFL CONTRACTING, INC in 125 SCHOOLHOUSE WAY, LEWISBURG, WV 24901 (NAICS 238350). OSHA activity number 345515274.
Where did this inspection happen?
- Establishment
- BFL CONTRACTING, INC
- Site address
- 125 SCHOOLHOUSE WAY
- City
- LEWISBURG
- State
- WV
- ZIP
- 24901
- Mailing
- PO BOX 2913, OCALA, FL 34471
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B04 I
- Issued
- Penalty
- Initial $2926.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(i):Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. a) 2nd floor Elevator shaft facing stairs: On or about September 2, 2021 and times prior employees walked within 2 feet of an elevator shaft. The elevator shaft was approximately 18 feet above aground and was not guarded and the employee did not utilize fall protection. b) 2nd floor elevator shaft upper level: On or about September 2, 2021 and times prior employees walked within 2 feet of an elevator shaft. The elevator shaft was approximately 21 feet above aground and was not guarded and the employee did not utilize fall protection. c) Floor opening: On or about September 2, 2021 and times prior employees walked within 2 feet of an opening in the floor. The floor opening was approximately 13 feet above aground and was not guarded and the employee did not utilize fall protection.
Recent events (2)
- — I (S) $0
- — Z (S) $2926
1926.1052 C01
- Issued
- Penalty
- Initial $2341.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge: a) Stairway to 2nd floor: On or about September 2, 2021, employees used the stairway in the center of the building to gain access to the 2nd floor. The stairway was equipped with 21 risers and was not equipped with a stairrail system on the unprotected side. b) Stairs to 1st Floor upper level: On or about September 2, 2021, employees used the stairway on the first floor to access the upper level on the first floor. The stairway was equipped with 6 risers and was not equipped with a stairrail system on the unprotected side.
Recent events (2)
- — I (S) $0
- — Z (S) $2341
1926.1052 C04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1052(c)(4):Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stairrail system and the stairway steps: a) Stairs to 2nd floor: On or about September 2, 2021 and times prior, employees used the stairs to access the 2nd floor to preform carpentry work. The stair rail system was not equipped with a mid rail resulting in an opening of approximately 38 inches between the stair and the bottom of the hand rail. b) Stairs to 1st floor upper level: On or about September 2, 2021 and time prior, employees used the stairs to access the first floor upper level to preform carpentry work. The stair rail system was not equipped with a mid rail resulting in an opening of approximately 36 inches between the stair and the bottom of the hand rail. c) Stairs to 2nd floor upper level: On or about September 2, 2021 and time prior, employees used the stairs to access the 2nd floor upper level to perform carpentry work. The stair rail system was not equipped with a mid rail resulting in an opening of approximately 36 inches between the stair and the bottom of the hand rail.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238350)
JAMESTOWN, RI—2026-07-10
A K I CARPENTRY INC
BROOKLYN, NY—2026-07-08
PALACE RESIDENTIAL CORP.
BROOKLYN, NY—2026-07-07
PRO PROPERTY RENO INC.
KENTON, OH—2026-07-01
SUNLIGHT WINDOWS AND EXTERIORS, LLC
ROBBINSVILLE, NJ—2026-06-30
FAST WRAP WINDOWS & DOORS, INC.
More inspections in WV
CHARLESTON, WV—2026-07-15
ASTECH CORPORATION
PARKERSBURG, WV—2026-07-15
UNKNOWN
VIENNA, WV—2026-07-15
PHOENIX ASSOCIATES, INC.
BRIDGEPORT, WV—2026-07-14
MID ATLANTIC METALWORKS INC.
BRIDGEPORT, WV—2026-07-14
INFINITY ELECTRIC & SERVICE COMPANY, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345515274.