Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: AMERI PRECISION METALS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AMERI PRECISION METALS in 40 CURRY AVENUE, CANONSBURG, PA 15317 (NAICS 332322). OSHA activity number 345604474.

Watch Ameri Precision Metals — free Get an email when a new federal OSHA severe-injury report for Ameri Precision Metals is published. One employer, no account, unsubscribe in one click.
Site address
40 CURRY AVENUE
City
CANONSBURG
State
PA
ZIP
15317
Mailing
40 CURRY AVENUE, CANONSBURG, PA 15317
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
68
Ownership type
A

2 citations on file for this inspection.

1910.212 A

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $10151.00 · Current $6000.00 Reduced
29 CFR  1910.212(a):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Facility, 40 Curry Avenue, Cannonsburg, PA: On or about  October 21st, 2021, employees were not protected from nip points and pinch points on the slitter head on CRS# 2.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $10151

1910.147 C01

Serious Gravity 5 1 instance 8 exposed
Issued
Penalty
Initial $8192.00 · Current $4000.00 Reduced
29 CFR  1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  (a) Facility, 40 Curry Avenue, Canonsburg, PA: On or about  October 21st, 2021, employees were not protected from stored energy while performing maintenance on equipment in the facility, in that the employer did not have a written lockout tagout procedure for equipment on the CRS #2 line.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $8192

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345604474.