Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,783,325Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TRANSFORM HOLDING, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TRANSFORM HOLDING, LLC in 8374 N. 4000 EAST FACILITY UNIT 8763, MANTENO, IL 60950 (NAICS 541614). OSHA activity number 345669592.

Watch Transform Holding, LLC — free Get an email when a new federal OSHA severe-injury report for Transform Holding, LLC is published. One employer, no account, unsubscribe in one click.
Site address
8374 N. 4000 EAST FACILITY UNIT 8763
City
MANTENO
State
IL
ZIP
60950
Mailing
3333 BEVERLY ROAD ALL-388B, HOFFMAN ESTATES, IL 60179
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541614
Employees
50
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8287.00 · Current $5500.00 Reduced
29 CFR  1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):   a.  On or about December 2, 2021, in the facility, the employer did not ensure the "Lockout /Tagout Energy Control Procedure" used by employees for service and maintenance of the Crown RR/RD 5200 Series, Serial Number 1A339366, clearly and specifically outlined the scope, purpose, authorization, rules and techniques to be utilized for the control of hazardous energy. The omission of the information including, but not limited to, the techniques for proper control of hazardous energy exposed employees to struck-by hazards.
Recent events (2)
  • — I (O) $5500
  • — Z (S) $8287

1910.147 C06 I

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8287.00 · Current $5500.00 Reduced
29 CFR  1910.147(c)(6)(i): The employer did not conduct an annual inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:   a.  On or about December 2,  2021, in the facility, the employer did not conduct periodic inspections of the energy control procedures at least annually to ensure that procedures and requirements of the standard were being followed.