1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: WILLIAMSON ROOFING, L.P.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WILLIAMSON ROOFING, L.P. in 5 PFEIFFER RD., BOERNE, TX 78006 (NAICS 332114). OSHA activity number 345692511.

Watch Williamson Roofing, L.P. — free Get an email when a new federal OSHA severe-injury report for Williamson Roofing, L.P. is published. One employer, no account, unsubscribe in one click.
Site address
5 PFEIFFER RD.
City
BOERNE
State
TX
ZIP
78006
Mailing
5 PFEIFFER ROAD, BOERNE, TX 78006
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332114
Employees
20
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4681.00 · Current $1872.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.  On or about December 16, 2021, and at times prior thereto, employees were performing maintenance on the Shear and Auto Brake machines without the employer developing procedures to isolate all energy sources, exposing the employees to the hazards of unexpected startup.
Recent events (2)
  • — I (S) $1872.4
  • — Z (S) $4681

1910.147 C05 I

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $4681.00 · Current $1872.00 Reduced
29 CFR 1910.147(c)(5)(i):Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing, or blocking of machines or equipment from energy sources.  On or about December 16, 2021, and at times prior thereto, the employer did not provide lockout tagout devices to control hazardous energy when employees were performing servicing and maintenance on machines and equipment, exposing employee's to hazards including, but not limited to caught-in moving parts.
Recent events (2)
  • — I (O) $1872.4
  • — Z (S) $4681

1910.147 C07 I

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $4681.00 · Current $1872.00 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program was understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees.   On or about December 16, 2021 and at times prior thereto, the employer did not provide training to ensure that employees had the knowledge and skills required to utilize energy controls, exposing the employees to the hazards of unexpected start-up of machines.
Recent events (2)
  • — I (O) $1872.4
  • — Z (S) $4681

1910.212 A02

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4681.00 · Current $1872.00 Reduced
29 CFR 1910.212(a)(2):Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible.  On or about December 16, 2021, and at times prior thereto, employees were working with the Drip Edge machine without the manufactured guards being affixed to the machine, exposing employees to the hazard of being caught-in moving parts.
Recent events (2)
  • — I (S) $1872.4
  • — Z (S) $4681

View WILLIAMSON ROOFING, L.P.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345692511.