1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PLASTIC INGENUITY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PLASTIC INGENUITY, INC. in 1017 PARK STREET, CROSS PLAINS, WI 53528 (NAICS 326199). OSHA activity number 345708556.

Watch Plastic Ingenuity, INC. — free Get an email when a new federal OSHA severe-injury report for Plastic Ingenuity, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1017 PARK STREET
City
CROSS PLAINS
State
WI
ZIP
53528
Mailing
P.O. BOX 130, CROSS PLAINS, WI 53528
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
250
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II D

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8287.00 · Current $6215.00 Reduced
29 CFR  1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.   On or about December 27, 2021, at the previously addressed job site, the energy control procedure for the thermorformer did not clearly and specifically outline the requirements for testing the machine to determine and verify the effectiveness of the pin and lock devices controlling the ovens gravity energy sources.   Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $6215
  • — Z (S) $8287

1910.147 C06 I

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.  a) On or about January 4, 2022, at the previously addressed job site, energy control procedures were not inspected at least annually.   Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).