OSHA Inspection: KEYSTONE CONSOLIDATED INDUSTRIES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KEYSTONE CONSOLIDATED INDUSTRIES, INC. in 7000 SW ADAMS STREET, PEORIA, IL 61641 (NAICS 331222). OSHA activity number 345800130.

Watch Keystone Consolidated Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Keystone Consolidated Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7000 SW ADAMS STREET
City
PEORIA
State
IL
ZIP
61641
Mailing
7000 SW ADAMS STREET, PEORIA, IL 61641
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331222
Employees
829
Ownership type
A

6 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $14502.00 · Current $10151.00 Reduced
29 CFR  1910.28(b)(1)(i):  Except as provided elsewhere in this section 29 CFR 1910.28, the employer had not ensured that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):  a.  On or about February 22, 2022, employees working at the North Circle of the Cleaning Department in Building 56 of the Wire Mill were exposed to fall hazards of over four feet because the employer had not ensured the pit where the acid tanks were housed was guarded.  b.  On or about February 22, 2022, employees working at the South Circle of the Cleaning Department in Building 56 of the Wire Mill were exposed to fall hazards of over four feet because the employer had not ensured the pit where the acid tanks were housed was guarded.
Recent events (2)
  • — I (S) $10151.4
  • — Z (S) $14502

1910.28 B03 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $11396.00 · Current $7977.00 Reduced
29 CFR  1910.28(b)(3)(iv):  The employer had not provided that each employee be protected from falling into a ladderway floor hole or ladderway platform hole by a guardrail system and toeboards erected on all exposed sides, except at the entrance to the hole, where a self-closing gate or an offset must be used:  On or about February 22, 2022, employees accessing the fixed ladder to perform crane inspections in the North Circle of the Cleaning Department in Building 56 of the Wire Mill were exposed to fall hazards of approximately 12 feet because the employer had not ensured a self-closing gate was located at the top of the fixed ladder.
Recent events (2)
  • — I (S) $7977.2
  • — Z (S) $11396

1910.178 L03 I G

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $11396.00 · Current $7977.00 Reduced
29 CFR  1910.178(l)(3)(i)(G):  Powered industrial truck operators had not received initial training on fork and attachment adaptation, operation, and use limitations:  On or about April 21, 2022, employees working at the North Circle of the Cleaning Department in Building 56 of the Wire Mill were exposed to struck-by hazards because employees operating the Hyster forklift had not received training regarding the weight capacity of the front end attachment used to transport coils of steel wire.
Recent events (2)
  • — I (S) $7977.2
  • — Z (S) $11396

1910.178 L03 I H

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.178(l)(3)(i)(H):  The employer had not evaluated employees knowledge and/or understanding of the powered industrial truck capacity and/or capability:  On or about April 21, 2022, employees working at the North Circle of the Cleaning Department in Building 56 of the Wire Mill were exposed to struck-by hazards because because employees operating the Hyster forklift had not received an evaluation regarding the weight capacity of the front end attachment used to transport coils of steel wire.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L03 I L

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.178(l)(3)(i)(L):  Powered industrial truck operators had not received initial training on operating limitations:  On or about April 21, 2022, employees working at the North Circle of the Cleaning Department in Building 56 of the Wire Mill were exposed to struck-by hazards because because employees operating the Hyster forklift had not received training regarding the weight capacity of the front end attachment used to transport coils of steel wire.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 O02

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $11396.00 · Current $7977.00 Reduced
29 CFR  1910.178(o)(2):  Load(s) were handled which exceeded the rated capacity of the industrial truck(s):   On or about April 21, 2022, employees working at the North Circle of the Cleaning Department in Building 56 of the Wire Mill were exposed to struck-by hazards because the the front end attachment used on the Hyster forklift  to transport coils of steel wire exceeded the maximum capacity of the attachment.