WICHITA, KS —
OSHA Inspection: CENTRAL STEEL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CENTRAL STEEL, INC. in 240 W. TENTH, WICHITA, KS 67201 (NAICS 332322). OSHA activity number 345826770.
Where did this inspection happen?
- Establishment
- CENTRAL STEEL, INC.
- Site address
- 240 W. TENTH
- City
- WICHITA
- State
- KS
- ZIP
- 67201
- Mailing
- PO BOX 1773, WICHITA, KS 67201
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 42
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.23 C11
- Issued
- Abate by
- Penalty
- Initial $5801.00 · Current $3481.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(11): The employer did not ensure that portable ladders used to gain access to an upper landing surface that have side rails that extend at least 3 feet (0.9 m) above the upper landing surface: At the Westside Paint Area, employee(s) engaged in truck loading activities on a trailer were exposed to fall hazards the portable ladder used to gain access area did not extend at least 3 feet above the landing surface.
Recent events (2)
- — I (S) $3480.6
- — Z (S) $5801
1910.28 B01 I
- Issued
- Abate by
- Penalty
- Initial $10151.00 · Current $6091.00 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): At the Westside Paint Area, employee(s) engaged in material handling activities were exposed to fall hazards of greater than 4 feet to the ground level below in that a guardrail or a fall protection system was not in place.
Recent events (2)
- — I (S) $6090.6
- — Z (S) $10151
1910.179 L03 III D
- Issued
- Abate by
- Penalty
- Initial $8702.00 · Current $4351.00 Reduced
General-duty citation text
29 CFR 1910.179(l)(3)(iii)(d):Pendant control stations were not kept clean, and/or their function labels were not kept legible: Employee(s) engaged in manufacturing activities were exposed to struck-by hazards in that pendant controls were unmarked in the following instances: 1) Chillo Pit Area: Pendant with no markings used with Harrington 3 ton Hoist 2) John Meyer Area: Pendant with no markings used with Harrington 3 ton Hoist
Recent events (2)
- — I (S) $4351
- — Z (S) $8702
1910.184 E01
- Issued
- Abate by
- Penalty
- Initial $10151.00 · Current $4060.00 Reduced
General-duty citation text
29 CFR 1910.184(e)(1):Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: At the Southwest Weld Area, employee(s) engaged in manufacturing activities were exposed to amputation and struck-by hazard in that the employer permitted the use of an alloy steel chain sling without a permanently affixed durable identification stating size, grade, rated capacity, and reach.
Recent events (2)
- — I (S) $4060.4
- — Z (S) $10151
1910.212 A03 II
- Issued
- Penalty
- Initial $5801.00 · Current $2320.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): At 235, employee(s) engaged in manufacturing activities at the Chicago 12-Speed Drill Press, were exposed to amputation hazards in that the point of operation was not guarded.
Recent events (2)
- — I (S) $2320.4
- — Z (S) $5801
1910.243 B02
- Issued
- Penalty
- Initial $8702.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.243(b)(2):Airhose and hose connections used for conducting compressed air to utilization equipment was not designed for the pressure and service to which they were subjected: At the Middle Fitting Area, employee(s) engaged in production activities were exposed to struck-by hazards in that the correct adaptor was not used to connect the tool, resulting in potential ejection of the tool.
Recent events (2)
- — I (S) $0
- — Z (S) $8702
1910.252 B02 III
- Issued
- Abate by
- Penalty
- Initial $8702.00 · Current $4351.00 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii):Workers and other persons adjacent to the welding area were not required to wear appropriate goggles, to protect them from the rays when noncombustible or flameproof screens or shields were not used: Employee(s) engaged in manufacturing activities were exposed to radiant energy or light radiation in that welding screens were not provided to adjacent employee(s).
Recent events (2)
- — I (S) $4351
- — Z (S) $8702
1910.253 B02 II
- Issued
- Abate by
- Penalty
- Initial $5801.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii):Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: In Eastside Bottle Area, employee(s) engaged in manufacturing activities were exposed to struck-by hazards and fire hazards into the employer did not secure the oxygen cylinders properly to prevent the cylinders from being knocked over or damaged.
Recent events (2)
- — I (S) $0
- — Z (S) $5801
1910.334 A02 I
- Issued
- Penalty
- Initial $4351.00 · Current $2176.00 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i):Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): In the East Weld Area, employee(s) engaged in manufacturing activities were exposed to electrical shock and burn hazards in that the extension cord connected to a Dewalt Portable grinder was pulling away from the connector.
Recent events (2)
- — I (S) $2175.5
- — Z (S) $4351
More inspections at CENTRAL STEEL, INC.
WICHITA, KS—2022-03-14 00:00:00
CENTRAL STEEL, INC.
WICHITA, KS—2018-12-18 00:00:00
CENTRAL STEEL INC.
WICHITA, KS—2018-01-25 00:00:00
CENTRAL STEEL, INC.
WICHITA, KS—2015-01-21 00:00:00
CENTRAL STEEL, INC.
WICHITA, KS—1986-01-15
CENTRAL STEEL INC.
View CENTRAL STEEL, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332322)
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
PITTSBURG, KS—2026-07-09
PROGRESSIVE PRODUCTS INC
NEW ROCHELLE, NY—2026-07-09
HEFTI HARBOR ELEC FAB & TOOLS
LAKEWOOD, WA—2026-07-08
WA317992020 - KRUEGER SHEET METAL CO
SOUTHAMPTON, MA—2026-07-07
LYMAN SHEET METAL CO., INC
More inspections in KS
WICHITA, KS—2026-07-10
DIVERSIFIED SERVICES, INC.
PITTSBURG, KS—2026-07-09
PROGRESSIVE PRODUCTS INC
WICHITA, KS—2026-07-09
FIGEAC AERO NORTH AMERICA, INC.
PITTSBURG, KS—2026-07-08
CDL ELECTRIC
WICHITA, KS—2026-07-08
IBT, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345826770.