Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PREMIER STEEL DOORS & FRAMES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PREMIER STEEL DOORS & FRAMES, INC. in 2840 STERLINGTON RD., MONROE, LA 71203 (NAICS 332321). OSHA activity number 345882906.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Premier Steel Doors & Frames, INC. — free Get an email when a new federal OSHA severe-injury report for Premier Steel Doors & Frames, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2840 STERLINGTON RD.
City
MONROE
State
LA
ZIP
71203
Mailing
2840 STERLINGTON RD., MONROE, LA 71203
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332321
Employees
25
Ownership type
A

3 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
May 11, 2022
Abate by
May 26, 2022
Penalty
Initial $7,252 · Current $4,351 Reduced
29 CFR  1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded.  On or about April 7, 2022, on the southside of the main framing area, an employee was performing "hinge" welding where employees hands were at the point of operations without guarding.
Recent events (2)
  • — I (S) $4351.2
  • — Z (S) $7252

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
May 11, 2022
Penalty
Initial $3,698 · Current $2,219 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  On or about April 7, 2022, an employee on the Northwest side of the plant while performing a fabrication task was using a "handy box" as an extension cord to power a floor fan.  The "handy box" is not UL listed or approved for use as an extension cord.
Recent events (2)
  • — I (S) $2218.8
  • — Z (S) $3698

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
May 11, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws.   On or about April 7, 2022, on the southeast side of the plant in the Styrene cutting area, the floor pedestal fan was being utilized with inadequate strain relief.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Premier Steel Doors & Frames, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345882906.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.