MONROE, LA —
OSHA Inspection: PREMIER STEEL DOORS & FRAMES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PREMIER STEEL DOORS & FRAMES, INC. in 2840 STERLINGTON RD., MONROE, LA 71203 (NAICS 332321). OSHA activity number 345882906.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PREMIER STEEL DOORS & FRAMES, INC.
- Site address
- 2840 STERLINGTON RD.
- City
- MONROE
- State
- LA
- ZIP
- 71203
- Mailing
- 2840 STERLINGTON RD., MONROE, LA 71203
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 25
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A03 II
- Issued
- May 11, 2022
- Abate by
- May 26, 2022
- Penalty
- Initial $7,252 · Current $4,351 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded. On or about April 7, 2022, on the southside of the main framing area, an employee was performing "hinge" welding where employees hands were at the point of operations without guarding.
Recent events (2)
- — I (S) $4351.2
- — Z (S) $7252
1910.303 B02
- Issued
- May 11, 2022
- Penalty
- Initial $3,698 · Current $2,219 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. On or about April 7, 2022, an employee on the Northwest side of the plant while performing a fabrication task was using a "handy box" as an extension cord to power a floor fan. The "handy box" is not UL listed or approved for use as an extension cord.
Recent events (2)
- — I (S) $2218.8
- — Z (S) $3698
1910.305 G02 III
- Issued
- May 11, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws. On or about April 7, 2022, on the southeast side of the plant in the Styrene cutting area, the floor pedestal fan was being utilized with inadequate strain relief.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Premier Steel Doors & Frames, INC.