OSHA Inspection: DIRECTORATE OF PUBLIC WORKS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DIRECTORATE OF PUBLIC WORKS in 601 ARTIC AVE, FORT GREELY, AK 99731 (NAICS 561110). OSHA activity number 346088131.

Watch Directorate OF Public Works — free Get an email when a new federal OSHA severe-injury report for Directorate OF Public Works is published. One employer, no account, unsubscribe in one click.
Site address
601 ARTIC AVE
City
FORT GREELY
State
AK
ZIP
99731
Mailing
P. O. BOX 31269, FORT GREELY, AK 99731
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561110
Employees
10
Ownership type
D

3 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(a)(3):  Exit route(s) were not kept free and unobstructed:  a) Warehouse - On or about July 18, 2022, boxes and pallets and product were obstructing egress path through an exit door, exposing employees to fire hazards.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 3 instances 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Admin: Along the back Wall:  On or about July 18, 2022, an extension cord was permanently mounted to the wall, exposing employees to fire and electrical hazards.  b) Admin: Desk No#1: On or about July 18, 2022, a Relocatable Power Tap was daisy chained, exposing employees to fire and electrical hazards.  c) Admin corner of the room: On or about July 18, 2022, a Relocatable Power Tap was daisy chained, exposing employees to fire and electrical hazards.
Recent events (1)
  • — Z (S) $0

1910.157 E02

Other-than-serious 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2):  Portable fire extinguishers were not visually inspected at least monthly:  a)  Throughout: On or about July 18, 2022, the employer provided portable fire extinguishers for employee use, but monthly visual inspections were not being performed, exposing employees to fire hazards.
Recent events (1)
  • — Z (O) $0

View DIRECTORATE OF PUBLIC WORKS's full OSHA safety record →