PEARLAND, TX —
OSHA Inspection: SHERMAN ROTO TANK, LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of SHERMAN ROTO TANK, LLC in 8521 INDUSTRIAL DRIVE, PEARLAND, TX 77584 (NAICS 332999). OSHA activity number 346121080.
Where did this inspection happen?
- Establishment
- SHERMAN ROTO TANK, LLC
- Site address
- 8521 INDUSTRIAL DRIVE
- City
- PEARLAND
- State
- TX
- ZIP
- 77584
- Mailing
- 8521 INDUSTRIAL DRIVE, PEARLAND, TX 77584
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 26
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.107 B09
- Issued
- Penalty
- Initial $5801.00 · Current $3481.00 Reduced
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction: a) At the facility, where combustibles such as cardboards and rags were stored within three feet of the spray booth, exposing employees to fire hazards.
Recent events (2)
- — I (S) $3481
- — Z (S) $5801
1910.107 B10
- Issued
- Penalty
- Initial $5801.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.107(b)(10): Illumination panels did not effectively isolate the spraying area from the area in which the lighting unit was located: a) At the facility, panels did not separate the spraying area from the light fixture exposing employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $5801
1910.107 B05 I
- Issued
- Penalty
- Initial $814.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained: a) At the spray booth, there was no visible gauge, audible alarm or pressure activated device installed to indicate or ensure that required air speed was maintained.
Recent events (2)
- — I (S) $0
- — Z (O) $814
1910.1200 E01
- Issued
- Penalty
- Initial $5801.00 · Current $3480.00 Reduced
2590
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) At the facility, the hazard communication program had not been implemented. Employees use hazardous substances such as Acrylic Modified Alkyd Enamel, a flammable, when spray painting.
Recent events (2)
- — I (S) $3480
- — Z (S) $5801
1910.1200 G08
- Issued
- Penalty
- Initial $0.00 · Current $0.00
2590
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required Safety Data Sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): a) At the facility, the employer did not maintain in the workplace copies of the required Safety Data Sheets for the chemicals found on site such as Acrylic Modified Alkyd Enamel and did not ensure the Safety Data Sheets were readily accessible in their work areas.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
2590
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) At the facility, employees exposed to hazardous substances such as, but not limited to, Acrylic Modified Alkyd Enamel, were not provided effective information and training on the hazardous chemicals in their work area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at SHERMAN ROTO TANK, LLC
PEARLAND, TX—2024-06-24 00:00:00
SHERMAN ROTO TANK, LLC
PEARLAND, TX—2022-07-19 00:00:00
SHERMAN ROTO TANK, LLC
View SHERMAN ROTO TANK, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332999)
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
HUNTINGDON VALLEY, PA—2026-07-09
METAL ALLIANCE, INC.
AITKIN, MN—2026-07-01
111512 - TEEMARK MANUFACTURING INC
SOUTH EL MONTE, CA—2026-06-29
VAGA INDUSTRIES
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source