1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: SHERMAN ROTO TANK, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of SHERMAN ROTO TANK, LLC in 8521 INDUSTRIAL DRIVE, PEARLAND, TX 77584 (NAICS 332999). OSHA activity number 346121080.

Watch Sherman Roto Tank, LLC — free Get an email when a new federal OSHA severe-injury report for Sherman Roto Tank, LLC is published. One employer, no account, unsubscribe in one click.
Site address
8521 INDUSTRIAL DRIVE
City
PEARLAND
State
TX
ZIP
77584
Mailing
8521 INDUSTRIAL DRIVE, PEARLAND, TX 77584
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
332999
Employees
26
Ownership type
A

6 citations on file for this inspection.

1910.107 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5801.00 · Current $3481.00 Reduced
29 CFR  1910.107(b)(9):  A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction:  a) At the facility,  where combustibles such as cardboards and rags were stored within three feet of the spray booth, exposing employees to fire hazards.
Recent events (2)
  • — I (S) $3481
  • — Z (S) $5801

1910.107 B10

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5801.00 · Current $0.00 Reduced
29 CFR  1910.107(b)(10):  Illumination panels did not effectively isolate the spraying area from the area in which the lighting unit was located:  a)  At the facility,  panels did not separate the spraying area from the light fixture exposing employees to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5801

1910.107 B05 I

Serious 1 instance 1 exposed
Issued
Penalty
Initial $814.00 · Current $0.00 Reduced
29 CFR  1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained:   a)  At the spray booth, there was no visible gauge, audible alarm or pressure activated device installed to indicate or ensure that required air speed was maintained.
Recent events (2)
  • — I (S) $0
  • — Z (O) $814

1910.1200 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5801.00 · Current $3480.00 Reduced

Hazardous substances 2590

29 CFR  1910.1200(e)(1):  The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a) At the facility, the hazard communication program had not been implemented.  Employees use hazardous substances such as Acrylic Modified Alkyd Enamel, a flammable, when spray painting.
Recent events (2)
  • — I (S) $3480
  • — Z (S) $5801

1910.1200 G08

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 2590

29 CFR  1910.1200(g)(8):  The employer did not maintain in the workplace copies of the required Safety Data Sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s):  a)  At the facility, the employer did not maintain in the workplace copies of the required Safety Data Sheets for the chemicals found on site  such as Acrylic Modified Alkyd Enamel and did not ensure the Safety Data Sheets were readily accessible in their work areas.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 2590

29 CFR  1910.1200(h)(1):  Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a)  At the facility,  employees exposed to hazardous substances such as, but not limited to, Acrylic Modified Alkyd Enamel, were not provided effective information and training  on the hazardous chemicals in their work area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View SHERMAN ROTO TANK, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346121080.