CHICAGO, IL —
OSHA Inspection: PRECISION PLATING COMPANY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PRECISION PLATING COMPANY, INC. in 4123 W. PETERSON AVE., CHICAGO, IL 60646 (NAICS 332813). OSHA activity number 346125230.
Where did this inspection happen?
- Establishment
- PRECISION PLATING COMPANY, INC.
- Site address
- 4123 W. PETERSON AVE.
- City
- CHICAGO
- State
- IL
- ZIP
- 60646
- Mailing
- 4123 W. PETERSON AVE., CHICAGO, IL 60646
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 150
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $13052.00 · Current $13052.00
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Plating Area- On or about August 1, 2022, the employer failed to establish a Lockout Tagout Program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performed any adjustments, cleaning, servicing or maintenance on machines, such as Plating Line 80, where the unexpected energization, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $13052
- — Z (S) $13052
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $13052.00 · Current $0.00 Reduced
General-duty citation text
1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Plating Area- On or about August 1, 2022, employees were exposed to machine hazards associated with moving parts and in-running nip points from the unexpected start-up and energization of Plating Line 80 when performing setup operations. The employer failed to implement energy control application steps as the machines were not shut down or turned off to perform adjustments [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine hazards. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $13052
More inspections at PRECISION PLATING COMPANY, INC.
CHICAGO, IL—2025-03-20
PRECISION PLATING COMPANY, INC.
CHICAGO, IL—2016-11-30 00:00:00
PRECISION PLATING COMPANY, INC.
CHICAGO, IL—2011-06-14 00:00:00
PRECISION PLATING COMPANY, INC.
CHICAGO, IL—1985-05-22 00:00:00
PRECISION PLATING COMPANY INC
View PRECISION PLATING COMPANY, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332813)
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WICHITA, KS—2026-07-15
PREMIER PROCESSING LLC
WARREN, MI—2026-07-14
AJAX METAL PROCESSING, INC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
WARSAW, IN—2026-07-08
SURFACE ENHANCEMENTS
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source