Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: SUNRUN INSTALLATION SERVICES INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUNRUN INSTALLATION SERVICES INC. in 52 CHURCH STREET, ROCHESTER, NH 03839 (NAICS 221114). OSHA activity number 346161532.

Watch Sunrun Installation Services INC. — free Get an email when a new federal OSHA severe-injury report for Sunrun Installation Services INC. is published. One employer, no account, unsubscribe in one click.
Site address
52 CHURCH STREET
City
ROCHESTER
State
NH
ZIP
03839
Mailing
16 PROGRESS ROAD B4, BILLERICA, MA 01821
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221114
Employees
231
Ownership type
A

6 citations on file for this inspection.

1926.502 D15 I

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $15000.00 Reduced
29 CFR 1926.502(d)(15)(I):  Anchorages used for attachment of personal fall arrest equipment were not designed, installed, and used as part of a complete personal fall arrest system which maintains a safety factor of at least two:    a) Main House- On or about August 14, 2022, an employee sustained injuries during a fall from a roof where the anchor point for their fall protection system failed. The SeamSAFE M6 standing seam metal roof anchor that the employer attached to the roof as part of a personal fall arrest system did not support at least twice the intended load.  b) Main House- On or about August 14, 2022, an employee working from the roof was not protected from a fall hazard where their personal fall arrest system was not complete; their personal fall arrest system did not include a deceleration device, as required by the SeamSafe M6 standing seam metal roof anchor and the SAFEWAZE SW-EX8000 removable trailing rope grab to which they were connected. The SeamSafe M6 standing seam metal roof anchor failed when it was impacted due to the employee falling from the roof without the use of a deceleration device.  c) Barn/Garage roof- On or about August 14, 2022, employees working from the roof were not protected from a fall hazard where a Guardian 2-way standing roof anchor was installed on a roof with a roof pitch greater than 4/12. The Guardian 2-way standing seam roof anchor was not rated for use on a roof with a pitch greater than 4/12.
Recent events (3)
  • — F (S) $15000
  • — C (S) $15625
  • — Z (S) $15625

1926.502 D15 II

Other-than-serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $4000.00 Reduced
29 CFR 1926.502(d)(15)(ii): Anchorages used for attachment of personal fall arrest systems were not designed, installed and used under the supervision of a qualified person:   Main House and Barn/Garage- On or about August 14, 2022,  employees working from the roofs were not protected from fall hazards where anchor points used as part of personal fall arrest systems were not installed by a qualified person.
Recent events (3)
  • — F (O) $4000
  • — C (S) $15625
  • — Z (S) $15625

1926.502 D17

Deleted Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $15625.00 · Current $0.00 Reduced
29 CFR  1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head:   a) Barn/Garage Roof- On or about August 14, 2022, an employee was not protected from fall related injuries where their personal fall arrest system utilized a positioning device connected at the employee's waist. The SAFEWAZE PC-070-W positioning/restraint lanyard was not rated for use in a personal fall arrest system.  b) Main House Roof- On or about August 14, 2022, employees were not protected from fall related injuries where their personal fall arrest systems utilized positioning devices connected at the employee's waist. The SAFEWAZE PC-070-W positioning/restraint lanyard was not rated for use in a personal fall arrest system.
Recent events (3)
  • — F (S) $0
  • — C (S) $15625
  • — Z (S) $15625

1926.1053 B05 I

Deleted Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $11162.00 · Current $0.00 Reduced
29 CFR  1926.1053(b)(5)(i):Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder.  a) Site- On or about August 14, 2022, employees working from a fiberglass extension ladder were not protected from a ladder collapse hazard where the ladder was erected with a horizontal distance from the top support to the foot of the ladder greater than one quarter of the working length of the ladder. The top of the ladder was supported against the wall at a height of 19 feet and the base of the ladder was 10 feet off of the wall.  b) Site- On or about August 14, 2022, employees working from a fiberglass extension ladder were not protected from a ladder collapse hazard where the ladder was erected with a horizontal distance from the top support to the foot of the ladder greater than one quarter of the working length of the ladder. The top of the ladder was supported against the wall at a height of 21 feet and the base of the ladder was 12 feet off of the wall.
Recent events (3)
  • — F (S) $0
  • — C (S) $11162
  • — Z (S) $11162

1926.416 A01

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $55810.00 · Current $3000.00 Reduced
29 CFR  1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  Site- On or about August 14, 2022, an employee was not protected from electric shock while working from a ladder directly next to the energized electrical service for the residence, which was not insulated.  Sunrun Solar was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1543185, citation number 1, item number 2 and was affirmed as a final order on January 6, 2022, with respect to a workplace located at 29 Bedford Street, Woburn, MA 01801.
Recent events (3)
  • — F (O) $3000
  • — C (R) $55810
  • — Z (R) $55810

1926.503 A02 II

Other-than-serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $55810.00 · Current $3000.00 Reduced
29 CFR  1926.503(a)(2)(ii):The employer did not assure that each employee, as necessary, had been trained by a competent person in the correct procedures for erecting, maintaining, disassembling and inspecting the fall protection systems to be used:  Site- On or about August 14, employees were not adequately trained in the correct procedures for erecting, maintaining, disassembling and inspecting fall protection systems that include the SeamSafe M6 standing seam metal roof anchor, Guardian 2-way standing seam metal roof anchor, SAFEWAZE SW-EX8000 removable trailing rope grab, and SAFEWAZE PC-070-W positioning/restraint lanyard.  Sunrun Solar was previously cited for a repeat violation of this occupational safety and health standard, which was contained in OSHA inspection number 1543185, citation number 2, item number 2 and was affirmed as a final order on January 6, 2022, with respect to a workplace located at 29 Bedford Street, Woburn, MA 01801.  Sunrun Inc. company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR  1926.503(a)(2)(ii), which was contained in OSHA inspection number 1191351,  citation number 1, item number 1B and was affirmed as a final order on January 23, 2017, with respect to a workplace located at 19 Pine Knoll Road, Southwick, MA 01077.
Recent events (3)
  • — F (O) $3000
  • — C (R) $55810
  • — Z (R) $55810

View SUNRUN INSTALLATION SERVICES INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346161532.