HOUSTON, TX —
OSHA Inspection: FORGED COMPONENTS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of FORGED COMPONENTS, INC. in 8881 HEMPSTEAD ROAD, HOUSTON, TX 77008 (NAICS 332111). OSHA activity number 346220726.
Where did this inspection happen?
- Establishment
- FORGED COMPONENTS, INC.
- Site address
- 8881 HEMPSTEAD ROAD
- City
- HOUSTON
- State
- TX
- ZIP
- 77008
- Mailing
- 8881 HEMPSTEAD ROAD, HOUSTON, TX 77008
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332111
- Employees
- 41
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.28 B01 I
- Issued
- Abate by
- Penalty
- Initial $7925.00 · Current $7925.00
General-duty citation text
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): On�or about�September 14, 2022, employees�were exposed�to a�fall hazard�exceeding four�feet when�working near�the water quench tank.
Recent events (2)
- — I (O) $7925
- — Z (S) $7925
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $6340.00 · Current $6340.00
General-duty citation text
29 CFR 1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about August 24, 2022, a maintenance employee was exposed to respiration hazards while wearing a 3M brand half-facepiece respirator without having been medically evaluated.
Recent events (2)
- — I (O) $6340
- — Z (S) $6340
1910.134 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: On or about August 24, 2022, a maintenance employee was exposed to respiration hazards while wearing a 3M brand half-facepiece respirator without having been fit tested before initial use.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $7925.00 · Current $7925.00
General-duty citation text
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. On or about September 2, 2022, employees were exposed to caught-in and struck-by hazards when performing service and /or maintenance on the H-40 Hyd-Mech saw without energy control procedures being utilized. b. On or about September 7, 2022, employees were exposed to caught-in and struck-by hazards when performing service and /or maintenance on the H-26 Hyd-Mech saw without energy control procedures being utilized. c. On or about September 14, 2022, employees were exposed to caught-in and struck-by hazards when performing service and /or maintenance on the H-32 Hyd-Mech saw without energy control procedures being utilized. d. On or about July 28, 2022, employees were exposed to caught-in hazards when performing service and /or maintenance on the water quench tank without energy control procedures being documented, developed, or utilized.
Recent events (2)
- — I (O) $7925
- — Z (S) $7925
1910.147 D03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): a. On or about September 2, 2022, employees were exposed to caught-in and struck-by hazards when performing service and /or maintenance on the H-40 Hyd-Mech saw without isolating the saw from the energy source. b. On or about September 7, 2022, employees were exposed to caught-in and struck-by hazards when performing service and /or maintenance on the H-26 Hyd-Mech saw without isolating the saw from the energy source. c. On or about September 14, 2022, employees were exposed to caught-in and struck-by hazards when performing service and /or maintenance on the H-32 Hyd-Mech saw without isolating the saw from the energy source. d. On or about July 28, 2022, employees were exposed to caught-in hazards when performing service and /or maintenance on the water quench tank without isolating all energy sources.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.218 F02 I
- Issued
- Abate by
- Penalty
- Initial $7925.00 · Current $7925.00
General-duty citation text
29 CFR 1910.218(f)(2)(i):Electrical power apparatus to hydraulic forging press(es) was not locked out when die(s) were being changed or maintenance was being performed on the press(es): On or about September 14, 2022, employees were exposed to struck-by hazard when changing out the dies on a hydraulic forging press without locking out the electrical power apparatus or hydraulic pumps.
Recent events (2)
- — I (S) $7925
- — Z (S) $7925
More inspections at FORGED COMPONENTS, INC.
NAVASOTA, TX—2012-04-11 00:00:00
FORGED COMPONENTS INC
NAVASOTA, TX—2010-07-16 00:00:00
FORGED COMPONENTS INC
View FORGED COMPONENTS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332111)
BENSALEM, PA—2026-06-16
SPECIALTY RING PRODUCTS, INC.
NEW BOSTON, MI—2026-05-12
ALCORTA USA INC
AMHERST, NY—2026-05-11
INDUSTRIAL WELDING & FABRICATING CO
WORCESTER, MA—2026-05-06
KOMTEK FORGE LLC
MC KENZIE, TN—2026-04-28
HAVEN STEEL PRODUCTS, INC.
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346220726.