Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: BIG CAT PLUMBING LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BIG CAT PLUMBING LLC in 271 W. DELRAY DR., PUEBLO WEST, CO 81007 (NAICS 238220). OSHA activity number 346246283.

Watch BIG CAT Plumbing LLC — free Get an email when a new federal OSHA severe-injury report for BIG CAT Plumbing LLC is published. One employer, no account, unsubscribe in one click.
Site address
271 W. DELRAY DR.
City
PUEBLO WEST
State
CO
ZIP
81007
Mailing
128 EAST MAIN STREET, FLORENCE, CO 81226
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
19
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4465.00 · Current $2679.00 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  a) On or before September 23, 2022, and at times prior, a safe means of egress was not provided for two employees working in a trench ranging from 6 to 8 feet in deep.  Although a 5-foot tall, A-frame ladder was located inside the trench, which was shorter than depth of the excavation, it was not secured from accidental displacement and was not used for its intended purpose.  This A-frame ladder did not provide a safe means of egress.
Recent events (2)
  • — I (S) $2679
  • — Z (S) $4465

1926.651 K01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6250.00 · Current $3750.00 Reduced
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions:  a) On or before September 23, 2022, and at times prior, the employer failed to ensure that daily inspections of the site and protective systems were conducted by a competent person. Two employees were working in an unprotected trench with vertical walls that ranged in depth from 6 to 8 feet. The employees were exposed to cave in hazards.
Recent events (2)
  • — I (S) $3750
  • — Z (S) $6250

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6250.00 · Current $3750.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c):  a)  On or about September 23, 2022, and at times prior, two employees were not protected from cave-in hazards while installing 4-inch sewer pipes in an unprotected trench.  The trench was approximately 3 feet wide and had vertical walls ranging from 6 to 8 feet in depth where the employees were working. The employees were exposed to cave in hazards.
Recent events (2)
  • — I (S) $3750
  • — Z (S) $6250

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346246283.