AUGUSTA, GA —
OSHA Inspection: GLOBAL SPECTRUM, LP (PA)
Federal Agency inspection · Health discipline
At a glance
On , OSHA opened a federal Agency health inspection of GLOBAL SPECTRUM, LP (PA) in 601 SEVENTH ST., AUGUSTA, GA 30901 (NAICS 713990). OSHA activity number 346358641.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GLOBAL SPECTRUM, LP (PA)
- Site address
- 601 SEVENTH ST.
- City
- AUGUSTA
- State
- GA
- ZIP
- 30901
- Mailing
- 601 SEVENTH ST., AUGUSTA, GA 30901
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713990
- Employees
- 325
- Ownership type
- A
Citations
13 citations on file for this inspection.
5(a)(1)
- Issued
- May 17, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $15,625 · Current $0 Reduced
11602340
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a) Mechanical Room: on or about November 18, 2022, an employee assigned to determine the source of a leak on the Heating Ventilation Air Conditioning (HVAC) system, was exposed to inhalation hazards from Freon R-123 and Freon R-134a.
Recent events (3)
- — J (S) $0
- — C (S) $15625
- — Z (S) $15625
1910.120 Q01
- Issued
- May 17, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $11,162 · Current $0 Reduced
2485
General-duty citation text
29 CFR 1910.120(q)(1): The employer did not develop and implement an emergency response plan to handle anticipated emergencies prior to commencement of emergency response operations: (a) Throughout the facility: On or about November 18, 2022, the employer failed to develop an emergency response plan to address anticipated emergencies prior to the commencement of the response to up to 1,400 pounds of a freon leak, exposing employees to inhalation hazards.
Recent events (3)
- — J (S) $0
- — C (S) $11162
- — Z (S) $11162
1910.134 E01
- Issued
- May 17, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $11,162 · Current $11,162
2485
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Mechanical Room: On November 18, 2022, an employee wore a full face WorkMask TM SCBA (Self Contained Breathing Apparatus) respirator to check the inside the chiller room. Employees had not been medically evaluated on respirators, exposing employees to respiratory hazards.
Recent events (3)
- — J (S) $11162
- — C (S) $11162
- — Z (S) $11162
1910.134 F02
- Issued
- May 17, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $11,162 · Current $11,162
2485
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (a) Mechanical Room: On November 18, 2022, an employee wore a full-face WorkMask TM SCBA (Self Contained Breathing Apparatus) respirator to check the inside the Mechanical room. Employees had not been fit tested on respirators, exposing employees to respiratory hazards.
Recent events (3)
- — J (S) $11162
- — C (S) $11162
- — Z (S) $11162
1910.134 H03 I
- Issued
- May 17, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $11,162 · Current $11,162
General-duty citation text
29 CFR 1910.134(h)(3)(i): Employer did not ensure that respirators were inspected as follows: all respirators used in routine situations inspected before each use and during cleaning; all respirators maintained for use in emergency situations inspected at least monthly and in accordance with the manufacturer's recommendations, and checked for proper function before and after each use; and emergency escape-only respirators inspected before being carried into the workplace for use: (a) Mechanical Room: On November 18, 2022, the employer failed to ensure a full face WorkMask TM SCBA (Self Contained Breathing Apparatus) respirator, used to enter a hazardous atmosphere, had been inspected and maintained as required.
Recent events (3)
- — J (S) $11162
- — C (S) $11162
- — Z (S) $11162
1910.134 K01
- Issued
- May 17, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $11,162 · Current $11,162
2485
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not provide effective training that covered the required elements in 1910.134(k)(1)(i) through 1910.134(k)(1)(vii) (a) Mechanical Room: On November 18, 2022, the employer failed to train employees on the necessity of the respirator, the inspection, the proper fit, checking the seal, usage, protection factor provided, the limitations of the respirator, emergency situations and actions to take if the respirator malfunctions, maintenance and cleaning of the respirator, medical signs and symptoms that prevent employees from use of respirators, exposing employees to respiratory hazard
Recent events (3)
- — J (S) $11162
- — C (S) $11162
- — Z (S) $11162
1910.134 G01 I A
- Issued
- May 17, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: (a) Mechanical Room: On November 18, 2022, the employer did not ensure an employee who utilized a full face WorkMask TM SCBA (Self Contained Breathing Apparatus) respirator was free of facial hair in order to ensure a correct seal for the mask, exposing the employee to respiratory hazards.
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
1910.147 C04 I
- Issued
- May 17, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $11,162 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Mechanical Room; On November 18, 2022, and times prior to, the employer did not ensure employee(s) performing service and maintenance of the Trane and York Chillers in the mechanical room were provide equipment specific procedures to identify and isolate energy sources, exposing employees to struck-by and/or electrical hazards. (b) Mechanical room; On November 18, 2022, and times prior to, employees performing maintenance on a boiler system were not provided equipment specific procedures to lock out sources of hazardous energy hazards, exposing employees to struck-by and/or electrical hazards.
Recent events (3)
- — J (S) $0
- — C (S) $11162
- — Z (S) $11162
1910.147 C05 II C 1
- Issued
- May 17, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $11,162 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(C)(1): Lockout devices were not substantial enough to prevent removal without the use of excessive force or unusual techniques, such as with the use of bolt cutters or other metal cutting tools: (a) Mechanical Room; On November 18, 2022, the employer did not ensure employee(s) performing service and maintenance of the Trane and York Chillers in the mechanical room were provided equipment to identify and isolate energy sources, exposing employees to struck by and electrical hazards. (b) Mechanical room; On November 18, 2022, employees performing maintenance on the electrical panel utilized plastic ties that were not substantial enough to prevent removal without the use of excessive force or unusual techniques to lock out sources of hazardous energy, exposing employees to electrical hazards.
Recent events (3)
- — J (S) $0
- — C (S) $11162
- — Z (S) $11162
1910.147 C07 I
- Issued
- May 17, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $11,162 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: (a) Mechanical Room: On November 18, 2022, employee(s) were exposed to struck-by and/or electrical hazards of the energy sources of the Trane/York Chillers and the 480-volt electrical cabinets for the boilers. Maintenance technician who performed maintenance and electrical work were not provided training on proper energy control methods and means for eliminating hazards.
Recent events (3)
- — J (S) $0
- — C (S) $11162
- — Z (S) $11162
1910.1200 E01
- Issued
- May 17, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $11,162 · Current $11,162
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Mechanical Room; On or about November 18, 2022, and times prior to, employees handled material such as but not limited to Freon (R123), while working in and around the pump room. A site-specific written hazard communication was not developed and implemented, a list of chemicals had not been developed and training was not conducted as required by the standard.
Recent events (3)
- — J (S) $11162
- — C (S) $11162
- — Z (S) $11162
1910.1200 E01 I
- Issued
- May 17, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet. (a) Mechanical Room; On or about November 18, 2022, and times prior to, employees handled material such as but not limited to Freon (R123), while working in and around the pump room. A list of hazardous chemicals had not been developed as required by the standard.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- May 17, 2023
- Abate by
- Jul 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Mechanical Room; On or about November 18, 2022, and times prior to, employees handled material such as but not limited to Freon (R123), while working in and around the pump room. Employees training was not conducted as required by the standard.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 713990)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346358641.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.