Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FPM HEAT TREATING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FPM HEAT TREATING, INC. in 1501 S. LIVELY BLVD., ELK GROVE VILLAGE, IL 60007 (NAICS 332811). OSHA activity number 346388747.

Watch FPM Heat Treating, INC. — free Get an email when a new federal OSHA severe-injury report for FPM Heat Treating, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1501 S. LIVELY BLVD.
City
ELK GROVE VILLAGE
State
IL
ZIP
60007
Mailing
1501 S. LIVELY BLVD., ELK GROVE VILLAGE, IL 60007
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332811
Employees
123
Ownership type
A

2 citations on file for this inspection.

1910.332 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $10046.00 · Current $7000.00 Reduced
29 CFR  1910.332(b)(1):Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  (a) Carbo Load Building Department, on December 13, 2022, the employer did not provide training to maintenance employees on safety related work practices that pertained to their respective job assignments such as working on live electrical equipment or troubleshooting on live electrical parts.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $10046

1910.335 A01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $10046.00 · Current $7000.00 Reduced
29 CFR  1910.335(a)(1)(i):Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:  (a) Carbo Load Building Department, on or about December 13, 2022, the employer did not ensure that employees troubleshooting on a 480 volt live electrical panel while using a Fluke 179 True-RMS Digital Multimeter were wearing electrical protective equipment, such as volt rated gloves.   (b) Carbo Load Building Department, on or about December 13, 2022, the employer did not ensure that employees troubleshooting on a 480 volt live electrical panel while using a Fluke 179 True-RMS Digital Multimeter were wearing electrical protective equipment, such as eye and face protection.  (c) Carbo Load Building Department, on or about December 13, 2022, the employer did not ensure that employees troubleshooting on a 480 volt live electrical panel while using a Fluke 179 True-RMS Digital Multimeter wore were wearing electrical protective equipment, such as fire retardant clothing.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $10046

View FPM HEAT TREATING, INC.'s full OSHA safety record →