BELLEVUE, OH —
OSHA Inspection: CENTER MANUFACTURING COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CENTER MANUFACTURING COMPANY in 540 GOODRICH ROAD, BELLEVUE, OH 44811 (NAICS 321920). OSHA activity number 346417553.
Where did this inspection happen?
- Establishment
- CENTER MANUFACTURING COMPANY
- Site address
- 540 GOODRICH ROAD
- City
- BELLEVUE
- State
- OH
- ZIP
- 44811
- Mailing
- 540 GOODRICH ROAD, BELLEVUE, OH 44811
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 5
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $4018.00 · Current $2009.00 Reduced
General-duty citation text
29 CFR 1910.37(a)(3):Exit route(s) were not kept free and unobstructed: a) Center Manufacturing Company, on or about December 14, 2022, at the address of 540 Goodrich Rd. Bellevue, OH; Employees working in the pallet notching department were exposed to fire hazards in that the nearest exit route was obstructed. The employer failed to provide unobstructed access to area of safe refuge beyond exit.
Recent events (2)
- — I (S) $2009
- — Z (S) $4018
1910.37 A04
- Issued
- Abate by
- Penalty
- Initial $4018.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.37(a)(4):Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: a) Center Manufacturing Company, on or about December 14, 2022, at the address of 540 Goodrich Rd. Bellevue, OH; Employees working in the palletizer room performing notching tasks were exposed to fire hazards in that the nearest exit door maintained an malfunction opening device. The employer failed to maintain the exit door in proper working order.
Recent events (2)
- — I (S) $0
- — Z (S) $4018
1910.37 B02
- Issued
- Abate by
- Penalty
- Initial $4018.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.37(b)(2):Each exit was not clearly visible and marked by a sign reading "Exit": a) Center Manufacturing Company, on or about December 14, 2022, at the address of 540 Goodrich Rd. Bellevue, OH; Employees working in the facility were exposed to fire hazards in that the main exit door had no emergency lighting. The employer failed to equip exit door with emergency lighting to facilitate locating exit in the event of a fire.
Recent events (2)
- — I (S) $0
- — Z (S) $4018
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $2344.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Center Manufacturing Company, on or about December 14, 2022, at the address of 540 Goodrich Rd. Bellevue, OH; Employees were exposed to crushing injuries such as but not limited to clearing jams on the palletizer in that the employer failed to have an energy control program in place.
Recent events (2)
- — I (S) $2344
- — Z (S) $4688
1910.178 G02
- Issued
- Abate by
- Penalty
- Initial $2679.00 · Current $1340.00 Reduced
General-duty citation text
29 CFR 1910.178(g)(2):Battery changing and charging installations for industrial trucks were not provided with facilities for flushing and neutralizing spilled electrolyte: a) Center Manufacturing Company, on or about December 14, 2022, at the address of 540 Goodrich Rd. Bellevue, OH; Employees who perform service and maintenance on the Doosan electric powered industrial trucks battery, were exposed to chemical burns from displaced acids. The employer failed to provide an eye wash station in location corrosive battery acids were present.
Recent events (2)
- — I (S) $1340
- — Z (S) $2679
1910.178 P01
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $2344.00 Reduced
General-duty citation text
29 CFR 1910.178(p)(1):Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) a) Center Manufacturing Company, on or about December 14, 2022, at the address of 540 Goodrich Rd. Bellevue, OH; Employees who operate or worked near where powered industrial trucks were operated, were exposed to struck by hazards in that the employer failed to remove powered industrial trucks from service that were in need of repair.
Recent events (2)
- — I (S) $2344
- — Z (S) $4688
1910.178 Q07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(q)(7):Industrial trucks were not examined before being placed in service: a) Center Manufacturing Company, on or about December 14, 2022, at the address of 540 Goodrich Rd. Bellevue, OH; Employees who operate or worked near where powered industrial trucks were operated, were exposed to struck by hazards in that the employer failed to ensure powered industrial trucks were inspected before being put in service.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L02 II
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(2)(ii):The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. a) Center Manufacturing Company, on or about December 14, 2022, at the address of 540 Goodrich Rd. Bellevue, OH; Employees who operate or worked near where powered industrial trucks were operated, were exposed to struck by hazards in that the employer failed to ensure powered industrial truck operators were adequately trained.
Recent events (2)
- — I (S) $0
- — Z (S) $4688
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $4018.00 · Current $2009.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Center Manufacturing Company, on or about December 14, 2022, at the address of 540 Goodrich Rd. Bellevue, OH; Employees tasked with loading the automated palletizer table were exposed to crushing/struck by injuries, in that the employer failed to guard the point of operation of the three downward firing nail guns.
Recent events (4)
- — P (S) $2009
- — P (S) $2009
- — I (S) $2009
1910.219 B01
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $2344.00 Reduced
General-duty citation text
29 CFR 1910.219(b)(1):Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv) a) Center Manufacturing Company, on or about December 14, 2022, at the address of 540 Goodrich Rd. Bellevue, OH; The employer failed to ensure the 11" flywheel located at the end of the 4-way notcher's auger was adequately guarded. Employees performing work tasks in proximity of the unguarded flywheel were exposed to caught in hazards.
Recent events (4)
- — P (S) $2344
- — P (S) $2344
- — I (S) $2344
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Center Manufacturing Company, on or about December 14, 2022, at the address of 540 Goodrich Rd. Bellevue, OH; Employees working near 4-way notcher's auger were exposed to caught in hazards, in that the employer failed to guard the top pulley located 63" above walking working surface.
Recent events (4)
- — P (S) $0
- — P (S) $0
- — I (S) $0
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $2679.00 · Current $1340.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i):Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Center Manufacturing Company, on or about December 14, 2022, at the address of 540 Goodrich Rd. Bellevue, OH; Employees working in the pallet notching department were exposed to electrical shock when accessing the 240v receptacle to power the auger. The employer failed to ensure 240v receptacles face plate was properly installed.
Recent events (2)
- — I (S) $1340
- — Z (S) $2679
More inspections in this industry (NAICS 321920)
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
WASHINGTON COURT HOUSE, OH—2026-07-09
HALLIDAY LUMBER, LLC
HENDERSON, TX—2026-06-30
W.D. TOWNLEY AND SON LUMBER COMPANY, INC.
BOYCEVILLE, WI—2026-06-26
SPECIALTY MANUFACTURING OF MENOMONIE, LLC
JACKSONVILLE, FL—2026-06-25
CHEP SERVICES, LLC
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346417553.