BLACK RIVER FALLS, WI —
OSHA Inspection: FLASH4.COM, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FLASH4.COM, LLC in 730 RED IRON ROAD, BLACK RIVER FALLS, WI 54615 (NAICS 323111). OSHA activity number 346472681.
Where did this inspection happen?
- Establishment
- FLASH4.COM, LLC
- Site address
- 730 RED IRON ROAD
- City
- BLACK RIVER FALLS
- State
- WI
- ZIP
- 54615
- Mailing
- 730 RED IRON ROAD, BLACK RIVER FALLS, WI 54615
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 18
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C05 II D
- Issued
- Abate by
- Penalty
- Initial $6875.00 · Current $4813.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s): (a) Throughout the facility; Lockout devices used to control energy isolation sources during service and maintenance activities did not include the identity of the employees who affixed the devices.
Recent events (2)
- — I (S) $4812.5
- — Z (S) $6875
1910.147 D03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Black Label Line, CEI B; An employee performed service and maintenance tasks not limited to, die replacement and set up on the CEI brand Label Die Cutting Machine, model CEI13, serial no. 355, without isolating equipment energy source(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Black Label Line, CEI B; An employee performed service and maintenance tasks not limited to, die replacement and set up on the CEI brand Label Die Cutting Machine, model CEI13, serial no. 355, without affixing lockout or tagout device(s) to equipment energy source(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $10313.00 · Current $7219.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Black Label Line, Rotoflex A; Machine guarding was not provided at all necessary locations to protect employees from ingoing nip point and/or shear point hazards on the Mark Andy brand Rotoflex Die Cutter and Laminator, model DLI-330, serial no. 9618756. (b) Black Label Line, Mark 7; Machine guarding was not provided at all necessary locations to protect employees from ingoing nip point and/or shear points hazards on the Mark Andy brand Rotary Printer and Die Cutter, model 830927Y-727C, serial no. 7642. (c) Black Label Line, CEI B; Machine guarding was not provided at all necessary locations to protect employees from ingoing nip point and/or shear points hazards on the CEI brand Label Die Cutting Machine, model CEI13, serial no. 355. (d) Color Printing Line, Mark 13 A; Machine guarding was not provided at all necessary locations to protect employees from ingoing nip point and/or shear points hazards on the Mark Andy brand Printing Press, model 2200-13F, serial no. 1203382-1. (e) Color Printing Line, Mark 17; Machine guarding was not provided at all necessary locations to protect employees from ingoing nip point and/or shear points hazards on the Mark Andy brand Printing Press, model 2200-17H, serial no. 1421365. (f) Color Printing Line, Mark 13 B; Machine guarding was not provided at all necessary locations to protect employees from ingoing nip point and/or shear points hazards on the Mark Andy brand Printing Press, model 2200-13F, serial no. 1247356.
Recent events (2)
- — I (S) $7219.1
- — Z (S) $10313
1910.219 F03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: (a)Black Label Line, Mark 7; A powered chain drive on the Mark Andy brand Rotary Printer and Die Cutter, model 830927Y-727C, serial no. 7642, was located approximately 3-feet above the floor and was not enclosed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 C04 I
- Issued
- Abate by
- Penalty
- Initial $5156.00 · Current $3609.00 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: (a) Colored Printing Line, Mark 17; A powered shaft end for the main webbing spool located on the Mark Andy brand Printing Press, model 2200-17H, serial no. 1421365, projected more than one half of the shaft's diameter.
Recent events (2)
- — I (S) $3609.2
- — Z (S) $5156
More inspections at FLASH4.COM, LLC
BLACK RIVER FALLS, WI—2026-03-03
FLASH4.COM, LLC
BLACK RIVER FALLS, WI—2020-03-03 00:00:00
FLASH4.COM, LLC
BLACK RIVER FALLS, WI—2019-08-19 00:00:00
FLASH4.COM, LLC.
View FLASH4.COM, LLC's full OSHA safety record →
More inspections in this industry (NAICS 323111)
MUSKEGON, MI—2026-07-08
GRAPHICS HOUSE PUBLISHING, INC
WARMINSTER, PA—2026-07-02
INNOTECH LASER
HERMITAGE, PA—2026-07-01
CCL CONTAINER, INC.
GREEN BAY, WI—2026-06-30
CHARTER NEXT GENERATION, INC.
LEHI, UT—2026-06-25
FIVE INC.
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346472681.