RANTOUL, IL —
OSHA Inspection: TRANSOM SYMPHONY OPCO, LLC DBA BEAUTY QUEST GROUP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TRANSOM SYMPHONY OPCO, LLC DBA BEAUTY QUEST GROUP in 205 SHELLHOUSE DRIVE, RANTOUL, IL 61866 (NAICS 325998). OSHA activity number 346705585.
Where did this inspection happen?
- Establishment
- TRANSOM SYMPHONY OPCO, LLC DBA BEAUTY QUEST GROUP
- Site address
- 205 SHELLHOUSE DRIVE
- City
- RANTOUL
- State
- IL
- ZIP
- 61866
- Mailing
- 205 SHELLHOUSE DRIVE, RANTOUL, IL 61866
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 402
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $12278.00 · Current $12278.00
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about May 11, 2023, employees were exposed to unexpected start-up or release of stored energy while performing servicing and maintenance activities on the Cappers, and the employer did not developed procedures that were documented to control hazardous energy.
Recent events (2)
- — I (S) $12278
- — Z (S) $12278
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $12278.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about May 11, 2023, an employee was exposed to caught-in and amputation hazards when performing maintenance and servicing on the Capper, Line 13 because the employer did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6). The maintenance employee was making adjustments on Line 13, and was not required to: (1) Know the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy, (2) Turn off and shut down the machine, (3) Physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source, (4) Affix lockout or tagout devices to each energy isolating device, (5) Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy shall be relieved, disconnected, restrained, and otherwise rendered safe. (6) Prior to starting work on machines that have been locked out or tagged out, verify that isolation and deenergization of the machine or equipment have been accomplished.
Recent events (2)
- — I (S) $0
- — Z (S) $12278
1910.303 G01
- Issued
- Penalty
- Initial $9822.00 · Current $6875.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: On or about May 16, 2023, employees were exposed to electrical shock because the electrical panels around the capper lines did not have sufficient access and working space, as indicated in Table S-1.
Recent events (2)
- — I (S) $6875
- — Z (S) $9822
More inspections at TRANSOM SYMPHONY OPCO, LLC DBA BEAUTY QUEST GROUP
RANTOUL, IL—2023-08-18 00:00:00
TRANSOM SYMPHONY OPCO, LLC DBA BEAUTY QUEST GROUP
RANTOUL, IL—2022-11-28 00:00:00
TRANSOM SYMPHONY OPCO, LLC DBA BEAUTY QUEST GROUP
View TRANSOM SYMPHONY OPCO, LLC DBA BEAUTY QUEST GROUP's full OSHA safety record →
More inspections in this industry (NAICS 325998)
CHARLOTTE, TX—2026-07-07
CLEMENTS FLUIDS
KINDRED, ND—2026-06-29
ICE CRYSTAL ENGINEERING
WAYNESVILLE, NC—2026-06-23
161409 - PREMIER MAGNESIA, LLC
SOUTH PLAINFIELD, NJ—2026-06-17
AVINTHIA INC
WARMINSTER, PA—2026-06-12
CRC INDUSTRIES, INCORPORATED
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346705585.