SAN ANTONIO, TX —
OSHA Inspection: HJD CAPITAL ELECTRIC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of HJD CAPITAL ELECTRIC in 5200 ROGERS RD, SAN ANTONIO, TX 78227 (NAICS 238210). OSHA activity number 346768328.
Where did this inspection happen?
- Establishment
- HJD CAPITAL ELECTRIC
- Site address
- 5200 ROGERS RD
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78227
- Mailing
- 5424 HWY 90 WEST, SAN ANTONIO, TX 78227
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.651 K01
- Issued
- Abate by
- Penalty
- Initial $14063.00 · Current $8438.00 Reduced
General-duty citation text
29 CFR 1926.651(k)(1):An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections were not made after every rainstorm or other hazard-increasing occurrence. Trench: On or about June 13, 2023, and at times prior thereto, an employee was exposed to struck-by hazards when working in an excavation that was not inspected to ensure that the system was pressurized prior to the start of the shift.
Recent events (2)
- — I (S) $8437.8
- — Z (S) $14063
1926.652 C02 I
- Issued
- Abate by
- Penalty
- Initial $14063.00 · Current $8438.00 Reduced
General-duty citation text
29 CFR 1926.652(c)(2)(i): Design of support systems, shield systems, or other protective systems that are drawn from the manufacturer's tabulated data were not in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer: Trench: On or about June 13, 2023, and at times prior thereto, an employee was exposed to struck-by hazards when working in an excavation that was not set up according to the manufacturer's tabulated data recommendations and limitations.
Recent events (2)
- — I (S) $8437.8
- — Z (S) $14063
1926.652 E01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.652(e)(1)(ii): Support systems were not installed and removed in a manner that protected employees from cave-ins, structural collapses, or from being struck by members of the support system: Trench: On or about June 13, 2023, and at times prior thereto, an employee was exposed to crush-by hazards while working in excavations where the support systems were not installed in a manner that protects employees from cave-ins, structural collapses, or being struck by members of the support system.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.652 C02 III
- Issued
- Penalty
- Initial $6026.00 · Current $3616.00 Reduced
General-duty citation text
29 CFR 1926.652(c)(2)(iii): Manufacturer's specifications, recommendations, and limitations, and manufacturer's approval to deviate from the specifications, recommendations, and limitations were not in written form at the job site during construction of during construction of the protective system. Trench: On or about June 13, 2023, and at times prior thereto, the employer did not maintain a copy of the manufacturer's information for the hydraulic shoring used at the site.
Recent events (2)
- — I (S) $3615.6
- — Z (S) $6026
1926.652 E01 I
- Issued
- Abate by
- Penalty
- Initial $14063.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.652(e)(1)(i): Members of support systems were not securely connected together to prevent sliding, falling, kickouts, or other predictable failure: Trench: On or about June 13, 2023, and at times prior thereto, employees were exposed to crush hazards while working in excavations where the support systems were not secured together in a manner that protects employees from sliding, falling, kickouts, or other predictable failures.
Recent events (2)
- — I (S) $0
- — Z (S) $14063
1926.652 G01 IV
- Issued
- Abate by
- Penalty
- Initial $14063.00 · Current $8438.00 Reduced
General-duty citation text
29 CFR 1926.652(g)(1)(iv): Employees were allowed in shields when shields were being installed, removed, or moved vertically: Trench: On or about June 13, 2023, and at times prior thereto, an employee was exposed to struck-by hazards when working inside an excavation which had shields being installed.
Recent events (2)
- — I (S) $8437.8
- — Z (S) $14063
More inspections at HJD CAPITAL ELECTRIC
SAN ANTONIO, TX—2009-05-27 00:00:00
HJD CAPITAL ELECTRIC
View HJD CAPITAL ELECTRIC's full OSHA safety record →
More inspections in this industry (NAICS 238210)
NEW YORK, NY—2026-07-17 00:00:00
VERGARA ELECTRICAL LLC
WASHINGTON, IL—2026-07-17 00:00:00
SUNRUN INSTALLATION SERVICES, INC.
KAHULUI, HI—2026-07-16 00:00:00
RISING SUN SOLAR ELECTRIC LLC
PARKVILLE, MD—2026-07-15 00:00:00
THE POWER SOURCE, INC.
SOUTH BARRINGTON, IL—2026-07-15 00:00:00
EDGE ELECTRICAL SYSTEMS, LLC
More inspections in TX
RICHMOND, TX—2026-07-17 00:00:00
CORNELIUS NURSERIES, INC.
HOUSTON, TX—2026-07-17 00:00:00
HOLLOWAY HOUSTON, INC.
BONHAM, TX—2026-07-17 00:00:00
VOLUNTARY PURCHASING GROUPS, INC.
SNYDER, TX—2026-07-16 00:00:00
RNWBL
WICHITA FALLS, TX—2026-07-16 00:00:00
UNITED RENTALS, INC.
Source