Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HJD CAPITAL ELECTRIC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of HJD CAPITAL ELECTRIC in 5200 ROGERS RD, SAN ANTONIO, TX 78227 (NAICS 238210). OSHA activity number 346768328.

Watch HJD Capital Electric — free Get an email when a new federal OSHA severe-injury report for HJD Capital Electric is published. One employer, no account, unsubscribe in one click.
Site address
5200 ROGERS RD
City
SAN ANTONIO
State
TX
ZIP
78227
Mailing
5424 HWY 90 WEST, SAN ANTONIO, TX 78227
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.651 K01

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $14063.00 · Current $8438.00 Reduced
29 CFR  1926.651(k)(1):An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections were not made after every rainstorm or other hazard-increasing occurrence.  Trench: On or about June 13, 2023, and at times prior thereto, an employee was exposed to struck-by hazards when working in an excavation that was not inspected to ensure that the system was pressurized prior to the start of the shift.
Recent events (2)
  • — I (S) $8437.8
  • — Z (S) $14063

1926.652 C02 I

Serious Gravity 10 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $14063.00 · Current $8438.00 Reduced
29 CFR 1926.652(c)(2)(i): Design of support systems, shield systems, or other protective systems that are drawn from the manufacturer's tabulated data were not in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer:  Trench: On or about June 13, 2023, and at times prior thereto, an employee was exposed to struck-by hazards when working in an excavation that was not set up according to the manufacturer's tabulated data recommendations and limitations.
Recent events (2)
  • — I (S) $8437.8
  • — Z (S) $14063

1926.652 E01 II

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.652(e)(1)(ii): Support systems were not installed and removed in a manner that protected employees from cave-ins, structural collapses, or from being struck by members of the support system:  Trench: On or about June 13, 2023, and at times prior thereto, an employee was exposed to crush-by hazards while working in excavations where the support systems were not installed in a manner that protects employees from cave-ins, structural collapses, or being struck by members of the support system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.652 C02 III

Serious Gravity 1 1 instance 6 exposed
Issued
Penalty
Initial $6026.00 · Current $3616.00 Reduced
29 CFR  1926.652(c)(2)(iii): Manufacturer's specifications, recommendations, and limitations, and manufacturer's approval to deviate from the specifications, recommendations, and limitations were not in written form at the job site during construction of during construction of the protective system.  Trench: On or about June 13, 2023,  and at times prior thereto, the employer did not maintain a copy of the manufacturer's information for the hydraulic shoring used at the site.
Recent events (2)
  • — I (S) $3615.6
  • — Z (S) $6026

1926.652 E01 I

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $14063.00 · Current $0.00 Reduced
29 CFR  1926.652(e)(1)(i): Members of support systems were not securely connected together to prevent sliding, falling, kickouts, or other predictable failure:  Trench: On or about June 13, 2023, and at times prior thereto, employees were exposed to crush hazards while working in excavations where the support systems were not secured together in a manner that protects employees from sliding, falling, kickouts, or other predictable failures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $14063

1926.652 G01 IV

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $14063.00 · Current $8438.00 Reduced
29 CFR  1926.652(g)(1)(iv): Employees were allowed in shields when shields were being installed, removed, or moved vertically:  Trench: On or about June 13, 2023, and at times prior thereto, an employee was exposed to struck-by hazards when working inside an excavation which had shields being installed.
Recent events (2)
  • — I (S) $8437.8
  • — Z (S) $14063

View HJD CAPITAL ELECTRIC's full OSHA safety record →