Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: BIG AXE FIREWOOD

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BIG AXE FIREWOOD in 5140 U.S. 51, BOULDER JUNCTION, WI 54512 (NAICS 321999). OSHA activity number 346829450.

Watch BIG AXE Firewood — free Get an email when a new federal OSHA severe-injury report for BIG AXE Firewood is published. One employer, no account, unsubscribe in one click.
Establishment
BIG AXE FIREWOOD
Site address
5140 U.S. 51
City
BOULDER JUNCTION
State
WI
ZIP
54512
Mailing
14427 N STATE HWY 122, SAXON, WI 54559
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321999
Employees
1
Ownership type
A

4 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4688.00 · Current $1000.00 Reduced
29 CFR  1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  The employer did not develop an energy control program including energy control procedures, employee training, and periodic inspections for employees performing servicing and maintenance work.
Recent events (3)
  • — F (S) $1000
  • — C (S) $4688
  • — Z (S) $4688

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.    The employer did not develop, document, and utilize energy control procedures for employees engaged in servicing and maintenance work including clearing jams and changing chain on firewood processor machine that exposed employees to exposed to potential struck-by and caught-in hazards that could result in serious injury or death.  Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locked-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:  On or about June 20, 2023, at the worksite located at 5140 South Highway 51 Boulder Junction, Wisconsin; the employer did not ensure that energy control application steps to control the pneumatic energy source of the Blockbuster, Inc. Model 22-22 Firewood Processor were understood by an employee operating the machine. The machine was not shut down or turned off prior to an employee pushing a stuck log towards the end of the conveyor system near the chain saw bar.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.132 D02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.132(d)(2):The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.  On or about July 13, 2023, at the worksite located at 5140 South Highway 51 Boulder Junction, Wisconsin; the employer could not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0