Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: AGAVE LD LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of AGAVE LD LLC in 8005 CEBERRY DRIVE, AUSTIN, TX 78759 (NAICS 561730). OSHA activity number 346912397.

Watch Agave LD LLC — free Get an email when a new federal OSHA severe-injury report for Agave LD LLC is published. One employer, no account, unsubscribe in one click.
Establishment
AGAVE LD LLC
Site address
8005 CEBERRY DRIVE
City
AUSTIN
State
TX
ZIP
78759
Mailing
501 COUNTY ROAD 107, GEORGETOWN, TX 78626
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561730
Employees
60
Ownership type
A

4 citations on file for this inspection.

1910.332 B01

Serious Gravity 10 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $11292.00 · Current $11292.00
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments.  On or about August 14, 2023, employees were performing tree-trimming operations near overhead power lines without being trained on safety-related work practices, exposing the employees to an electrical hazard.
Recent events (2)
  • — I (S) $11292
  • — Z (S) $11292

1910.333 C03 I A 1

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11292.00 · Current $11292.00
29 CFR 1910.333(c)(3)(i)(A)(1): When an unqualified person was working in an elevated position near overhead lines with voltages to ground rated at 50 kV or below, the location was not such that the person and the longest conductive object he or she could contact cannot come closer to any unguarded, energized overhead line of 10 ft. for voltages to ground 50kV or below.  On or about August 14, 2023, employees were performing tree-trimming operations near overhead power lines while using an aluminum pole saw without maintaining the required distance, exposing the employees to an electrical hazard.
Recent events (2)
  • — I (S) $11292
  • — Z (S) $11292

1910.333 C07

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11292.00 · Current $0.00 Reduced
29 CFR 1910.333(c)(7): Portable ladders did not have non conductive siderails if they were used where the employee or the ladder could contact exposed energized parts.  On or about August 14, 2023, employees were performing tree-trimming operations near overhead power lines while using an aluminum extension ladder, exposing the employees to an electrical hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11292

1910.335 A02 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11292.00 · Current $0.00 Reduced
29 CFR 1910.335(a)(2)(i): When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts.  On or about August 14, 2023, employees were performing tree-trimming operations near overhead power lines with a non-insulated aluminum pole saw, exposing the employees to an electrical hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11292

RNWBL