PICKTON, TX —
OSHA Inspection: FRONTIER FORESTRY, LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of FRONTIER FORESTRY, LLC in FM 269, PICKTON, TX 75471 (NAICS 561730). OSHA activity number 346918550.
Where did this inspection happen?
- Establishment
- FRONTIER FORESTRY, LLC
- Site address
- FM 269
- City
- PICKTON
- State
- TX
- ZIP
- 75471
- Mailing
- 1020 36 STREET SOUTH, PARIS, TX 75460
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561730
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.269 A02 I A
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $3516.00 Reduced
General-duty citation text
29 CFR 1910.269(a)(2)(i)(A): Each employee was not trained in, and familiar with, the safety-related work practices, safety procedures, and other safety requirements in this section that pertain to his or her job assignments: a) On or about August 17, 2023, and times prior thereto, employees were exposed to electrical hazards while working near overhead power lines without first being trained.
Recent events (2)
- — I (S) $3516
- — Z (S) $4688
1910.269 B01 I
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.269(b)(1)(i): Cardiopulmonary resuscitation (CPR) and first aid training when performing work on or associated with exposed lines or equipment energized at 50 volts or more, persons were not trained in first aid including cardiopulmonary resuscitation (CPR) were not available: a) On or about August 17, 2023, and at times prior thereto, where employees who were performing tree trimming operations around overhead power lines did not have the assistance of a first aid trained employee.
Recent events (2)
- — I (S) $0
- — Z (S) $4688
1910.269 C01 II
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.269(c)(1)(ii): The employer did not ensure that the employee in charge conducted a job briefing that met paragraphs (c)(2) though (c)(4) of this section with the employees involved before they start each job: a) On or about August 17, 2023, and at times prior thereto, employees who were performing line clearance were not briefed on hazards associated with the job, work procedures involved, special precautions, energy-source controls, and personal protective equipment requirements.
Recent events (2)
- — I (S) $0
- — Z (S) $4688
1910.333 C03
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $3516.00 Reduced
General-duty citation text
29 CFR 1910.333(c)(3): When work was to be performed near overhead lines, the lines were not de-energized and grounded, nor were other protective measures provided before work was started. Where lines are to be de-energized, arrangements were not made with the person or organization that operates or controls the electric circuits involved to de-energize and ground them. a) On or about August 17, 2023, and times prior thereto, employees were exposed to electrical hazards while working near overhead power lines with 7,200 volts that were not de-energized and grounded prior to the work beginning.
Recent events (2)
- — I (S) $3516
- — Z (S) $4688
1910.333 C03 I A 1
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.333(c)(3)(i)(A)(1): When an unqualified person was working in an elevated position near overhead lines with voltages to ground rated at 50 kV or below, the location was not such that the person and the longest conductive object he or she could contact came closer than 10 ft. (305 cm) to any unguarded, energized overhead line: a) On or about August 17, 2023, and times prior there, unqualified employees were exposed to electrical hazards while working within 10 feet of 7,200 volts of energized overhead power lines in an elevated position.
Recent events (2)
- — I (S) $0
- — Z (S) $4688
More inspections in this industry (NAICS 561730)
HELENDALE, CA—2026-07-17 00:00:00
IGNACIO PEREZ LANDSCAPE AND MAINTENANCE
PALM COAST, FL—2026-07-16 00:00:00
J & J TREE EXPERTS, INC.
NEW BOSTON, NH—2026-07-16 00:00:00
ANDREW GRANT'S TREE SERVICE
LAKE PARK, NC—2026-07-15 00:00:00
161553 - QUALITY ARBOR SERVICES INC.
SACRAMENTO, CA—2026-07-15 00:00:00
JOE'S LANDSCAPING & CONCRETE INC.
More inspections in TX
RICHMOND, TX—2026-07-17 00:00:00
CORNELIUS NURSERIES, INC.
HOUSTON, TX—2026-07-17 00:00:00
HOLLOWAY HOUSTON, INC.
BONHAM, TX—2026-07-17 00:00:00
VOLUNTARY PURCHASING GROUPS, INC.
SNYDER, TX—2026-07-16 00:00:00
RNWBL
WICHITA FALLS, TX—2026-07-16 00:00:00
UNITED RENTALS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346918550.