OSHA Inspection: CATERPILLAR INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of CATERPILLAR INC. in 2416 MID AMERICA INDUSTRIAL DRIVE, BOONVILLE, MO 65233 (NAICS 333120). OSHA activity number 346924079.

Watch Caterpillar INC. — free Get an email when a new federal OSHA severe-injury report for Caterpillar INC. is published. One employer, no account, unsubscribe in one click.
Establishment
CATERPILLAR INC.
Site address
2416 MID AMERICA INDUSTRIAL DRIVE
City
BOONVILLE
State
MO
ZIP
65233
Mailing
2416 MID AMERICA INDUSTRIAL DRIVE, BOONVILLE, MO 65233
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333120
Employees
120
Ownership type
A

5 citations on file for this inspection.

1910.134 D01 III

Other-than-serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $16131.00 · Current $10000.00 Reduced
29 CFR  1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  On August 21, 2023, the employer failed to fully document its evaluation and assessment of nitrogen in the air during ?Pre-Startup Cleanout? tasks performed by an operator on Cryogenic Deflasher Machine CBD-6 Serial # 7015, M10010 BVCHS-0715.
Recent events (3)
  • — F (O) $10000
  • — C (S) $16131
  • — Z (S) $16131

1910.134 D02 I

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $16131.00 · Current $0.00 Reduced
29 CFR  1910.134(d)(2)(i):The employer did not provide either a full facepiece pressure demand SCBA certified by NIOSH for a minimum service life of thirty minutes or a combination full facepiece pressure demand supplied-air respirator with  auxiliary self-contained air supply.  Employees were exposed to an asphyxiation hazard in that the employer did not provide employees with respirators for use in IDLH atmospheres and oxygen deficient atmospheres in and around the Cryogenic Deflasher machines.  Employees were exposed to oxygen deficient atmospheres while performing tasks including but not limited to "Pre-Startup Cleanout" of Cryogenic Deflasher machines.
Recent events (3)
  • — F (S) $0
  • — C (S) $16131
  • — Z (S) $16131

1910.134 D02 III

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $16131.00 · Current $0.00 Reduced
29 CFR  1910.134(d)(2)(iii):When the atmosphere was oxygen deficient, it was not considered to be IDLH.  Employees were exposed to asphyxiation hazards in that the employer did not assess or treat Cryogenic Deflasher workspaces, as immediately dangerous to life and health (IDLH) in the presence of expected, but unmeasured, oxygen-deficient atmospheres. The employer did not implement elements of the respiratory protection standard required for IDLH work exposures. Employees were exposed to oxygen-deficient atmospheres while performing tasks including but not limited to "Pre-Startup Cleanout" of Cryogenic Deflasher machines.
Recent events (3)
  • — F (S) $0
  • — C (S) $16131
  • — Z (S) $16131

1910.134 G03

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(g)(3):  For all IDLH atmospheres, the employer did not ensure that the requirements of 29 CFR 1910.134(g)(3)(i) - (vi) were met.  Employees were exposed to an asphyxiation hazard in that the employer did not treat oxygen deficient atmospheres in and around the Cryogenic Deflasher machines as immediately dangerous to life and health (IDLH). The employer did not implement the required elements of the respiratory protection standard where employees were exposed to IDLH atmospheres while performing tasks including but not limited to "Pre-Startup Cleanout" of Cryogenic Deflasher machines. The employer failed to ensure one or more employee is outside the IDLH atmosphere during entry, determine and implement a system of communication, ensure the employee outside IDLH space is trained in emergency rescue, designate a person to be notified before the person outside the IDLH space enters to rescue, ensure a designee, once notified, would  provide necessary assistance appropriate to the situation, and equip the employee outside IDLH space with pressure demand SCBA or other positive pressure supplied air with auxiliary SCBA, retrieval equipment that didn't increase overall entry risk or equivalent means to rescue when standard retrieval equipment is inappropriate.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.305 G02 III

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $9218.00 · Current $0.00 Reduced
29 CFR  1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:   The employer is failing to protect employees from electrical shock, fire, or burn hazards. This was most recently documented at a work site located at 2416 Mid America Industrial Dr, Boonville, Missouri. Employees were exposed to serious injuries due to electrical shock, fire, or burns, in that electrical  cord powering the  Presto Lift was found to be in disrepair with damaged strain relief exposing outer insulation.
Recent events (3)
  • — F (S) $0
  • — C (S) $9218
  • — Z (S) $9218

View CATERPILLAR INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346924079.