ELLICOTTVILLE, NY —
OSHA Inspection: FITZPATRICK & WELLER INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FITZPATRICK & WELLER INC. in 12 MILL STREET, ELLICOTTVILLE, NY 14731 (NAICS 423310). OSHA activity number 346984594.
Where did this inspection happen?
- Establishment
- FITZPATRICK & WELLER INC.
- Site address
- 12 MILL STREET
- City
- ELLICOTTVILLE
- State
- NY
- ZIP
- 14731
- Mailing
- 12 MILL STREET, ELLICOTTVILLE, NY 14731
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423310
- Employees
- 26
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $10938.00 · Current $5500.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 09/15/2023, in the Boiler Room, lockout procedures were not utilized when a boiler operator was servicing the boiler. The employee inadvertently reached into the rotary of the boiler while it was running to remove a buildup of sawdust when the blade came in contact with their finger resulting in a partial fingertip amputation. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $5500
- — Z (S) $10938
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. a) On or about 09/19/2023, in the Boiler Room, employees that are required to Lockout machines such as, but not limited the boiler, when performing maintenance or servicing activities such as cleaning the rotary of the boiler, were not trained as authorized employees. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at FITZPATRICK & WELLER INC.
TOWN OF MANSFIELD, NY—1990-03-28
FITZPATRICK & WELLER, INC.
ELLICOTTVILLE, NY—1988-11-16
FITZPATRICK & WELLER, INC.
ELLICOTTVILLE, NY—1985-09-04
FITZPATRICK & WELLER, INC.
ELLICOTTVILLE, NY—1984-11-21
FITZPATRICK & WELLER INC
Ellicottville, NY—1981-10-14
FITZPATRICK & WELLER INC
View FITZPATRICK & WELLER INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423310)
WILSON, NC—2026-07-09
161516 - STEPHENSON MILLWORK COMPANY, INC.
WILSON, NC—2026-07-09
161511 - WEB-DON, INCORPORATED
SANTA ANA, CA—2026-07-09
NGY GROUP (ORANGE COUNTY) INC.
HAVANA, FL—2026-07-08
BOISE CASCADE WOOD PRODUCTS, L.L.C.
OAKLAND, CA—2026-06-30
VAN MATRE LUMBER CO., INC.
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346984594.