Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BIG TEX GENERAL CONTRACTOR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BIG TEX GENERAL CONTRACTOR in 13015 FM 1957 POTRANCO ROAD, SAN ANTONIO, TX 78245 (NAICS 238130). OSHA activity number 347094781.

Watch BIG TEX General Contractor — free Get an email when a new federal OSHA severe-injury report for BIG TEX General Contractor is published. One employer, no account, unsubscribe in one click.
Site address
13015 FM 1957 POTRANCO ROAD
City
SAN ANTONIO
State
TX
ZIP
78245
Mailing
1900 COUNTY ROAD 361, LAVERNIA, TX 78121
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
7
Ownership type
A

5 citations on file for this inspection.

1926.300 A

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $2009.00 · Current $1205.00 Reduced
29 CFR 1926.300(a): Hand tool(s), power tool(s) or similar equipment were not maintained in a safe condition:  13015 FM 1957 Potranco Road, San Antonio, TX 78245: On or about November 8, 2023, and at times prior thereto, workers were exposed to electrical hazards while using an impact handheld gun that had damage to the outer sheath of the electrical cord.
Recent events (2)
  • — I (S) $1205.4
  • — Z (S) $2009

1926.416 E01

Serious Gravity 1 2 instances 3 exposed
Issued
Penalty
Initial $2009.00 · Current $1205.00 Reduced
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  a) 13015 FM 1957 Potranco Road, San Antonio, TX 78245:  On or about November 8, 2023, and at times prior thereto, employees were exposed to an electrical hazard while using a frayed extension cord to power a rechargeable battery.    b) 13015 FM 1957 Potranco Road, San Antonio, TX 78245:  On or about November 8, 2023, and at times prior thereto, employees were exposed to an electrical hazard while using a frayed extension cord to power a handheld impact gun.
Recent events (2)
  • — I (S) $1205.4
  • — Z (S) $2009

1926.451 C02 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3349.00 · Current $2009.00 Reduced
29 CFR  1926.451(c)(2)(iv): Front-end loaders and similar pieces of equipment were used to support scaffold platforms when they were not specifically designed by the manufacturer for such use:   13015 FM 1957 Potranco Road, San Antonio, TX 78245: On or about November 8, 2023, and at times prior thereto, employees were exposed to a fall hazard while working in a man-made basket while being lifting by a CAT Model TL642C that was not approved by the manufacturer.
Recent events (2)
  • — I (S) $2009.4
  • — Z (S) $3349

1926.451 C02 V

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2)(v): The employer used forklifts to support scaffold platforms without ensuring that the entire platform was attached to the fork and that the forklift was not moved horizontally while the platform was occupied: Note:  Preamble to Subpart L promulgated new paragraph (c)(2)(iv) & (v) in final rule to provide guidance. Added provision requires that in the case of fork-lifts, the entire scaffold platform be secured to the forklift:    13015 FM 1957 Potranco Road, San Antonio, TX 78245: On or about November 8, 2023, and times prior thereto, employees were exposed to fall hazards while riding inside a man-made personnel work platform attached to a CAT Model TL642C Frontend Loader that was not secured to the forks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.602 D

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2679.00 · Current $1607.00 Reduced
29 CFR  1926.602(d): The employer did not certify that each operator had been trained and evaluated as required by paragraph 29 CFR 1910.178(l):Note: The requirements applicable to construction work under paragraph (d) of this section are identical to those set forth at paragraph (l) of 29 CFR 1910.178:  13015 FM 1957 Potranco Road, San Antonio, TX 78245; On or about November 8, 2023, and at times prior thereto, the employer did not ensure employees operating a CAT Model TL642C Frontend Loader were certified on their training and evaluation prior to use.
Recent events (2)
  • — I (S) $1607.4
  • — Z (S) $2679