Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CP CONVERTERS INC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of CP CONVERTERS INC in 15 GRUMBACHER ROAD, YORK, PA 17402 (NAICS 323111). OSHA activity number 347138000.

Watch CP Converters INC — free Get an email when a new federal OSHA severe-injury report for CP Converters INC is published. One employer, no account, unsubscribe in one click.
Establishment
CP CONVERTERS INC
Site address
15 GRUMBACHER ROAD
City
YORK
State
PA
ZIP
17402
Mailing
15 GRUMBACHER ROAD, YORK, PA 17402
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
270
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 270 exposed
Issued
Abate by
Penalty
Initial $16131.00 · Current $16131.00
OSHA Act of 1970 Section 5(a)(1)?The employer did not furnish employment and a place of employment that were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a crushing hazard:   a)	15 Grumbacher Road, York, PA, on or about November 30, 2023, an employee engaged in material handling activities was struck by and caught between hazards created when a Power Industrial Truck was not restored to a safe operating condition before being returned to service.     Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $16131
  • — Z (S) $16131

1910.178 P01

Deleted Serious Gravity 10 1 instance 270 exposed
Issued
Abate by
Penalty
Initial $16131.00 · Current $0.00 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s)   a) 15 Grumbacher Road York, PA, On or about November 30, 2023, employees engaged in material handling activities were exposed to struck-by and caught between hazards created when Powered Industrial Trucks were not restored to safe operating conditions by the removal of cable ties on the brakes, used for towing, before returning to service by maintenance.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $16131

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347138000.