HOUSTON, TX —
OSHA Inspection: HOT SHOT FINAL MILE, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HOT SHOT FINAL MILE, LLC in 12333 SOWDEN ROAD, HOUSTON, TX 77080 (NAICS 492110). OSHA activity number 347209074.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HOT SHOT FINAL MILE, LLC
- Site address
- 12333 SOWDEN ROAD
- City
- HOUSTON
- State
- TX
- ZIP
- 77080
- Mailing
- 12333 SOWDEN ROAD, HOUSTON, TX 77080
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 492110
- Employees
- 20
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.157 C01
- Issued
- Apr 2, 2024
- Penalty
- Initial $4,839 · Current $2,420 Reduced
General-duty citation text
29 CFR 1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:(a) On or about January 11, 2024, employees at the pallet workshop of warehouse were exposed to smoke inhalation and burns as there was a fire extinguisher blocked by work equipment and material.
Recent events (2)
- — I (S) $2419.5
- — Z (S) $4839
1910.303 B02
- Issued
- Apr 2, 2024
- Abate by
- Apr 16, 2024
- Penalty
- Initial $8,067 · Current $4,034 Reduced
General-duty citation text
29 CFR 1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:(a) 1. On or about January 11, 2024, at the pallet workshop of the warehouse employees were exposed to an electrical hazard where an electrical power strip improperly mounted next to a work table. 2. On or about January 11, 2024, next to the fridge in the warehouse employees were exposed to an electrical hazard where an electrical extension cord was used on a permanent basis.
Recent events (2)
- — I (S) $4033.5
- — Z (S) $8067
1910.305 G01 IV C
- Issued
- Apr 2, 2024
- Abate by
- Apr 16, 2024
- Penalty
- Initial $8,067 · Current $4,034 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C):Flexible cords and cables were used where run through doorways, windows, or similar openings. On or about January 11, 2024, next to the refrigerator in the warehouse employees were exposed to an electrical hazard as there was an extension cord running underneath a doorway exposing employees to electrical hazards.
Recent events (2)
- — I (S) $4033.5
- — Z (S) $8067
1910.1200 G01
- Issued
- Apr 2, 2024
- Abate by
- Apr 25, 2024
- Penalty
- Initial $6,453 · Current $3,227 Reduced
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use. On or about January 11, 2024, at the pallet workshop of the warehouse employees were exposed to upper respiratory and explosive hazards as the employer did not have safety data sheets for chemicals such as propane to power forklifts, PB penetrating catalyst, marking paint and CLR.
Recent events (2)
- — I (S) $3226.5
- — Z (S) $6453
1910.1200 H01
- Issued
- Apr 2, 2024
- Abate by
- Apr 25, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about January 11, 2024, at the pallet workshop of the warehouse employees were not trained when exposed to upper respiratory hazards and explosive hazards as employees while using chemicals such as propane to power forklifts, PB penetrating catalyst, marking paint and CLR.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at HOT Shot Final Mile, LLC
View HOT Shot Final Mile, LLC's full OSHA safety record →
More inspections in this industry (NAICS 492110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347209074.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.