1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: POLYFOAM, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of POLYFOAM, LLC in 2355 PROVIDENCE ROAD, NORTHBRIDGE, MA 01534 (NAICS 326140). OSHA activity number 347271090.

Watch Polyfoam, LLC — free Get an email when a new federal OSHA severe-injury report for Polyfoam, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
POLYFOAM, LLC
Site address
2355 PROVIDENCE ROAD
City
NORTHBRIDGE
State
MA
ZIP
01534
Mailing
2355 PROVIDENCE ROAD POB 906, NORTHBRIDGE, MA 01534
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326140
Employees
120
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $14518.00 · Current $13670.00 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: 2355 Providence Road, Northbridge, MA:  On and before February 9, 2024, employees performed maintenance and servicing activities on Molding Press #9 without a documented energy control procedure to direct the control of potentially hazardous energy.
Recent events (2)
  • — I (S) $13670
  • — Z (S) $14518

1910.147 C06 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(6)(i):  The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:   2355 Providence Road, Northbridge, MA:  On and before February 9, 2024,  the employer had not performed a comprehensive periodic inspection of energy control procedures for all multi-energy sources machines, including the Molding Press #9 machine, at least annually to verify that each procedure was adequate and being properly used by employees. *Abatement Notes:  A periodic inspection shall include the following elements:  - Appointment of an authorized employee to inspect each unique procedure for deviations and inadequacies during an energy control task  - A review by inspector with each authorized employee, of that employee's responsibilities under each energy control procedure they are authorized to use - Certification that the periodic inspections had been performed by identifying the machines or equipment on which the energy control procedures were being utilized, the dates of the inspections, the employees included in the inspections, and the persons performing the inspections *Abatement notes are intended only to provide clarity regarding existing requirements under the law or agency policies. Abatement notes do not create (or diminish) legal obligations under the Occupational Safety and Health Act.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 A05

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $8296.00 · Current $0.00 Reduced
29 CFR  1910.178(a)(5):The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: 2355 Providence Road, Northbridge, MA:  On and before February 9, 2024, employees operated powered industrial trucks with a boom attachment that was not included on the data plates to identify approximate weight of the truck and capacity at maximum elevation with load laterally centered.
Recent events (2)
  • — I (O) $0
  • — Z (S) $8296

1910.178 Q07

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.178(q)(7):  Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift: 2355 Providence Road, Northbridge, MA:  On and before February 9, 2024, some powered industrial trucks were being used during multiple shifts and were only being inspected once per day.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347271090.