1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: DOLLAR GENERAL CORPORATION/DOLGENCORP LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DOLLAR GENERAL CORPORATION/DOLGENCORP LLC in 282 S DUPONT HWY, DOVER, DE 19901 (NAICS 452319). OSHA activity number 347308777.

Watch Dollar General Corporation/Dolgencorp LLC — free Get an email when a new federal OSHA severe-injury report for Dollar General Corporation/Dolgencorp LLC is published. One employer, no account, unsubscribe in one click.
Site address
282 S DUPONT HWY
City
DOVER
State
DE
ZIP
19901
Mailing
100 MISSION RIDGE ATTN: TRISH SVEBEK - RISK MANAGEMENT, GOODLETTSVILLE, TN 37072
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
452319
Employees
7
Ownership type
A

9 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $15211.00 · Current $15211.00
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  a) Dollar General store at 288 S. Dupont Hwy. in Dover, DE 19901: On or about February 29, 2024, the employer placed a cylinder of helium sitting on the floor in the register area without any type of protection to prevent the cylinder from being knocked and/or falling over possibly striking the employee and/or damaging the valve causing the cylinder to discharge uncontrollably which would cause a projectile and struck by hazard.
Recent events (1)
  • — Z (S) $15211

1910.141 C01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $12676.00 · Current $12676.00
29 CFR 1910.141(c)(1)(i): Toilet facilities were not provided in accordance with TABLE J-1 of this Section:  a) Dollar General store at 288 S. Dupont Hwy. in Dover, DE 19901: On or about February 29, 2024, employees did not have toilet facilities made available during their shifts when they were required to work alone in the store creating adverse health effects for the employees.
Recent events (1)
  • — Z (S) $12676

1910.151 C

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $10140.00 · Current $10140.00
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  a) Dollar General store at 288 S. Dupont Hwy. in Dover, DE 19901: On or about February 29, 2024, employees used corrosive cleaning materials and did not have any type of emergency eye wash facility.
Recent events (1)
  • — Z (S) $10140

1910.303 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $15211.00 · Current $15211.00
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  a) Dollar General store at 288 S. Dupont Hwy. in Dover, DE 19901: On or about February 29, 2024, employees were exposed to electrical hazards when they worked in and around broken/altered circuit breakers and/or light switches that created shock/electrocution hazards.  The Dollar General Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.303(b)(1), which was contained in OSHA inspection number 1467642, citation number 1, item number 1 and was affirmed as a final order on July 28, 2020, with respect to a workplace located at 960 Lancaster Avenue, Columbia, PA 17512.
Recent events (1)
  • — Z (S) $15211

1910.303 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Dollar General store at 288 S. Dupont Hwy. in Dover, DE 19901: On or about February 29, 2024, employees were exposed to electrical hazards when the employer had a metal electrical box temporarily installed to supply power to the coolers in the front of the store.
Recent events (1)
  • — Z (S) $0

1910.303 F01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a) Dollar General store at 288 S. Dupont Hwy. in Dover, DE 19901: On or about February 29, 2024, the site had three electrical panels the employees could access but was not aware what components were being powered by the specific panels to remove an electrical hazard the employees would be exposed to.
Recent events (1)
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a) Dollar General store at 288 S. Dupont Hwy. in Dover, DE 19901: On or about February 29, 2024, employees were exposed to live electrical wiring shock hazards and accidental contact from an unguarded electric receptacle and openings in electrical panels.  The Dollar General Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.303(g)(2)(i), which was contained in OSHA inspection number 1636051, citation number 1, item number 1 and was affirmed as a final order on May 16, 2023, with respect to a workplace located at 1888 McClellandtown Road, Masontown, PA 15461.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Dollar General store at 288 S. Dupont Hwy. in Dover, DE 19901: On or about February 29, 2024, employees used and were exposed to flexible extension cords substituted for fixed wiring creating shock and electrical burn hazards.
Recent events (1)
  • — Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $7604.00 · Current $7604.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) Dollar General store at 288 S. Dupont Hwy. in Dover, DE 19901: On or about February 29, 2024, the employer did not provide training on hazardous chemicals to be used on the site nor did the employer provide SDS's for the employees to reference in case there was an exposure.
Recent events (1)
  • — Z (S) $7604

View DOLLAR GENERAL CORPORATION/DOLGENCORP LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347308777.