EASTON, PA —
OSHA Inspection: BI-STATE CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BI-STATE CONSTRUCTION, INC. in THE MARQUIS APARTMENTS 27 S 3RD ST, EASTON, PA 18042 (NAICS 237310). OSHA activity number 347349375.
Where did this inspection happen?
- Establishment
- BI-STATE CONSTRUCTION, INC.
- Site address
- THE MARQUIS APARTMENTS 27 S 3RD ST
- City
- EASTON
- State
- PA
- ZIP
- 18042
- Mailing
- 1500 WEST UHLER ROAD, EASTON, PA 18042
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237310
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.651 I03
- Issued
- Penalty
- Initial $4702.00 · Current $3056.00 Reduced
General-duty citation text
29 CFR 1926.651(i)(3):Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures: a) Construction site, intersection of 3rd and Pine Streets - On or about March 13, 2024, employees walked and worked on and around a section of pavement that had been undermined and were exposed to serious injury in the event of collapse.
Recent events (2)
- — I (S) $3056.3
- — Z (S) $4702
1926.651 K01
- Issued
- Abate by
- Penalty
- Initial $3918.00 · Current $2547.00 Reduced
General-duty citation text
29 CFR 1926.651(k)(1):An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift: (a) Construction site, intersection of 3rd and Pine Streets - On or about March 13, 2024, the employer did not ensure a competent person was on site to perform necessary inspections during excavating a trench for a sewer line.
Recent events (2)
- — I (S) $2546.7
- — Z (S) $3918
1926.652 C02 I
- Issued
- Penalty
- Initial $3134.00 · Current $2037.00 Reduced
General-duty citation text
29 CFR 1926.652(c)(2)(i): Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data were not in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer: (a) Construction site, intersection of 3rd and Pine Streets - On or about March 13, 2024, an employee worked in a trench more than 5 feet deep while inside a Speed Shore Modular Aluminum Panel Shield that was installed with mis-installed and missing spreader bars.
Recent events (2)
- — I (S) $2037.1
- — Z (S) $3134
1926.652 C02 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.652(c)(2)(iii): Manufacturer's specifications, recommendations, and limitations, and manufacturer's approval to deviate from the specifications, recommendations, and limitations were not in written form at the jobsite during construction of t (a) Construction site, intersection of 3rd and Pine Streets - On or about March 13, 2024, an employee worked in a trench more than 5 feet deep while inside a Speed Shore Modular Aluminum Panel Shield that was installed with mis-spaced and missing spreader bars and manufacturer tabulated data was not on site during construction of the protective system.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Penalty
- Initial $1998.00 · Current $1260.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) Construction site, intersection of 3rd and Pine Streets - On or about March 13, 2024, an employee worked in a trench more than 5 feet deep while inside a Speed Shore Modular Aluminum Panel Shield used a portable ladder for access and egress that did not extend 3 feet above the landing surface.
Recent events (2)
- — I (S) $1259.9
- — Z (S) $1998
More inspections at BI-STATE CONSTRUCTION, INC.
UPPER BLACK EDDY, PA—2025-10-15
BI-STATE CONSTRUCTION, INC.
EASTON, PA—2016-10-04 00:00:00
BI-STATE CONSTRUCTION, INC.
EASTON, PA—2001-09-19 00:00:00
BI-STATE CONSTRUCTION INC.
View BI-STATE CONSTRUCTION, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237310)
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
REDDING, CA—2026-07-15
ALLEN GILL CONSTRUCTION INC
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source