2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: AGTEGRA COOPERATIVE

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of AGTEGRA COOPERATIVE in 13345 341ST AVENUE, ROSCOE, SD 57471 (NAICS 424510). OSHA activity number 347382475.

Watch Agtegra Cooperative — free Get an email when a new federal OSHA severe-injury report for Agtegra Cooperative is published. One employer, no account, unsubscribe in one click.
Establishment
AGTEGRA COOPERATIVE
Site address
13345 341ST AVENUE
City
ROSCOE
State
SD
ZIP
57471
Mailing
908 LAMONT STREET SOUTH, ABERDEEN, SD 57401
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
18
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $5494.00 · Current $3000.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a)Agtegra Cooperative at 13345 341st Avenue, Roscoe, SD 57471: On or about and at times prior to March 28, 2024, the employer did not ensure the C-11 BC-2280 Reclaim Conveyor system was properly guarded to prevent employees from having any part of their body in the danger zones during machine operations. This hazard exposed employees to caught in, crushing, and amputation hazards.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5494

1910.219 H01

Serious Gravity 5 6 instances 5 exposed
Issued
Abate by
Penalty
Initial $12929.00 · Current $8000.00 Reduced
29 CFR 1910.219(h)(1): Projecting keys, setscrews, or other projections in revolving parts were not removed, made flush, or guarded by metal covers:  (a)Agtegra Cooperative at 13345 341st Avenue, Roscoe, SD 57471: On or about and at times prior to March 28, 2024, the employer did not ensure spinning drive mechanisms with projecting bolt heads on the C-3 Drag Conveyor motor DC-1100 was effectively guarded.  This condition exposed employees to caught-in hazards associated with the unguarded drive mechanism.  (b)Agtegra Cooperative at 13345 341st Avenue, Roscoe, SD 57471: On or about and at times prior to March 28, 2024, the employer did not ensure spinning drive mechanisms with a projecting keyway and projecting set screw head on the C-6 Dry Grain Fill Conveyor #2 was effectively guarded.  This condition exposed employees to caught-in hazards associated with the unguarded drive mechanism.  (c)Agtegra Cooperative at 13345 341st Avenue, Roscoe, SD 57471: On or about and at times prior to March 28, 2024, the employer did not ensure spinning drive mechanisms with projecting bolt heads on the C-1 Drag Conveyor motor DC-4055 was effectively guarded. This condition exposed employees to caught-in hazards associated with the unguarded drive mechanism.  (d)Agtegra Cooperative at 13345 341st Avenue, Roscoe, SD 57471: On or about and at times prior to March 28, 2024, the employer did not ensure spinning drive mechanisms with projecting bolt heads on the C-1 Drag Conveyor motor DC-4040 was effectively guarded. This condition exposed employees to caught-in hazards associated with the unguarded drive mechanism.  (e)Agtegra Cooperative at 13345 341st Avenue, Roscoe, SD 57471: On or about and at times prior to March 28, 2024, the employer did not ensure spinning drive mechanisms with projecting bolt heads on the C-1 Drag Conveyor motor DC-1000 was effectively guarded. This condition exposed employees to caught-in hazards associated with the unguarded drive mechanism.  (f)Agtegra Cooperative at 13345 341st Avenue, Roscoe, SD 57471: On or about and at times prior to March 28, 2024, the employer did not ensure spinning drive mechanisms with projecting bolt heads on the C-10 Drag Conveyor motor DC-5016 was effectively guarded. This condition exposed employees to caught-in hazards associated with the unguarded drive mechanism.
Recent events (2)
  • — I (S) $8000
  • — Z (S) $12929

1910.303 B07 I

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $5494.00 · Current $3000.00 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:  (a)Agtegra Cooperative at 13345 341st Avenue, Roscoe, SD 57471: On or about and at times prior to March 28, 2024, the employer did not ensure that an opening in an electrical panel was effectively closed, in that employees were exposed to live electrical circuits associated with a missing breaker in the L2 208-volt breaker panel located at the southwest corner in the Agronomy Center Warehouse Area.  This condition exposed employees to shock and electrocution as well as fire hazards associated with exposed wiring on the electrical box.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5494

1910.303 G01

Serious Gravity 1 2 instances 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a)Agtegra Cooperative at 13345 341st Avenue, Roscoe, SD 57471: On or about and at times prior to March 28, 2024, the employer did not ensure that the electrical panels in the southwest corner of the Agronomy Center Warehouse Area had sufficient access and working space in that materials were obstructing the panels.  This condition exposed employees to electrical hazards due to the blocked electrical panels.  (b)Agtegra Cooperative at 13345 341st Avenue, Roscoe, SD 57471: On or about and at times prior to March 28, 2024, the employer did not ensure that the electrical panel on the north wall in the Maintenance Area of the Agronomy Center had sufficient access and working space in that materials were obstructing the panel.  This condition exposed employees to electrical hazards due to the blocked electrical panel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View AGTEGRA COOPERATIVE's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347382475.