Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BUZZI UNICEM, USA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BUZZI UNICEM, USA in 2415 PIER STREET, MEMPHIS, TN 38113 (NAICS 327320). OSHA activity number 347458788.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Buzzi Unicem, USA — free Get an email when a new federal OSHA severe-injury report for Buzzi Unicem, USA is published. One employer, no account, unsubscribe in one click.
Establishment
BUZZI UNICEM, USA
Site address
2415 PIER STREET
City
MEMPHIS
State
TN
ZIP
38113
Mailing
P.O. BOX 13204, MEMPHIS, TN 38113
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
11
Ownership type
A

4 citations on file for this inspection.

1917.112 C03

Serious Gravity 10 1 instance 11 exposed
Issued
Jul 10, 2024
Penalty
Initial $12,098 · Current $7,259 Reduced
29 CFR 1917.112(c)(3): The top surface of guardrails installed after October 3, 1983, was not 42 inches, plus or minus 2 inches high:  (a) Buzzi Memphis Terminal, gangway platform: On or about 5/02/2024, and at times prior, the employer exposed employees to falls greater than four feet, in that a work platform on the gangway raised the floor level so that the top rail was at a height of 26 inches.
Recent events (2)
  • — I (S) $7258.8
  • — Z (S) $12098

1910.303 F01

Other-than-serious 1 instance 11 exposed
Issued
Jul 10, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  (a) Buzzi working barge, North side, beneath and West of gangway: On or about 5/03/2024, and at times prior, the employer exposed employees to possible shock hazards, in that the breakers inside of a 480-volt panel box were not labeled to indicate their purpose.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 11 exposed
Issued
Jul 10, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a) Buzzi working barge, workshop, South wall: On or about 5/03/2024, and at times prior, the employer exposed employees to electrical shock hazards, in that the area in front of three electrical panel boxes was being used for storage blocking access to the electrical panels.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B03 III

Other-than-serious 4 instances 11 exposed
Issued
Jul 10, 2024
Penalty
Initial $971 · Current $583 Reduced
29 CFR 1910.305(b)(3)(iii): Covers for boxes were not permanently marked "HIGH VOLTAGE".  (a)  Buzzi working barge, North side, beneath and West of gangway: On or about 5/03/2024, and at times prior, the employer exposed employees to possible shock hazards, in that the outside of a 480-volt panel box was not labeled with warning signs.  (b) Buzzi working barge, workshop, South wall, left panel box: On or about 5/03/2024, and at times prior, the employer exposed employees to possible shock hazards, in that the outside of a 480-volt panel box was not labeled with warning signs.  (c) Buzzi working barge, workshop, South wall, center panel box: On or about 5/03/2024, and at times prior, the employer exposed employees to possible shock hazards, in that the outside of a 480-volt panel box was not labeled with warning signs.  (d) Buzzi working barge, workshop, South wall, right panel box: On or about 5/03/2024, and at times prior, the employer exposed employees to possible shock hazards, in that the outside of a 480-volt panel box was not labeled with warning signs.
Recent events (2)
  • — I (O) $582.6
  • — Z (O) $971

View Buzzi Unicem, USA's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347458788.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.